Operation
Standalone Configuration
In a standalone mode, the onAir IP Panel 1 can be controlled through the display menu, the control knobs,
and/or the preset buttons.
CCT Control
In CCT Control mode, the control knobs have the following functions:
•
<DIM/INTENSITY>: Increase or decrease the dimmer value, from 00.0–100%.
•
<+/-GRN/HUE>: Increase or decrease the green level, from -0.25–0.25.
•
<CCT/SATURATION>: Increase or decrease the correlated color temperature, from 2800–8000K.
To set the product to CCT Control mode, press one of the preset buttons, or:
1. Go to the Static main level.
2. Select the CCT Control option.
Preset Buttons
Pressing one of the 8 preset buttons will automatically set the product to CCT Control mode.
•
Press <Preset A/B> to toggle between the A presets (factory-defined) and the B presets (custom).
•
To save a custom preset:
1. Press <Preset A/B> until the upper right corner of the display reads P/B.
2. Set the control knobs as desired in CCT Control mode.
3. Press and hold the button for the desired preset. (Master Mode Preset Save will flash on the
display).
HSV Control
In HSV Control mode, the control knobs have the following functions:
•
<DIM/INTENSITY>: Increase or decrease the dimmer value, from 00.0–100%.
•
<+/-GRN/HUE>: Increase or decrease the hue value, from 000–360°.
•
<CCT/SATURATION>: Increase or decrease the saturation, from 00.0–100%.
To set the product to HSV Control mode:
1. Go to the Static main level.
2. Select the HSV Control option.
XY Control
In HSV Control mode, the control knobs have the following functions:
•
<DIM/INTENSITY>: Increase or decrease the dimmer value, from 00.0–100%.
•
<+/-GRN/HUE>: Increase or decrease the X coordinate value, from 0.00–0.850.
•
<CCT/SATURATION>: Increase or decrease the Y coordinate value, from 0.00–0.850.
To set the product to HSV Control mode:
1. Go to the Static main level.
2. Select the XY Control option.
Preset CCTs
To set the onAir IP Panel 1 to a preset correlated color temperature through the display menu:
1. Go to the Static main level.
2. Select the Preset CCTs option.
3. Select the preset correlated color temperature, from 2800K, 2900K, 3000K, 3100K, 3200K,
3300K, 3400K, 3500K, 3600K, 3700K, 3800K, 3900K, 4000K, 4100K, 4200K, 4300K, 4400K,
4500K, 4600K, 4700K, 4800K, 4900K, 5000K, 5100K, 5200K, 5300K, 5400K, 5500K, 5600K,
5700K, 6000K, 6500K, 7000K, 7500K, or 8000K.
4. Set the Dimmer from 000–255.
5. Set the Hue from -25–25.
Manual Color Mixer
To mix a custom static color through the display menu of the onAir IP Panel 1:
1. Go to the Static main level.
2. Select the Manual Color Mixer option.
3. Select the color value to edit, from Red, Green, Blue, and White.
4. Set the selected color value from 000–255.
5. Repeat until the color is set as desired.
onAir IP Panel 1 User Manual Rev. 3
21