Charging time for battery
capacity, approx.
1 .3 Ah–1 .5 Ah
min
2 .0 Ah
min
2 .6 Ah–3 .0 Ah
min
4 .0 Ah
min

Operation

Starting Operation
 Observe the mains voltage! The voltage of the power
supply must correspond with the data given on the name-
plate of the battery charger. Battery chargers marked with
230 V can also be operated with 220 V.
Charging Procedure
The charging procedure starts as soon as the mains plug of
the battery charger is plugged into the socket outlet and the
battery 1 is inserted into the charging compartment 3.
Due to the intelligent charging method, the charging condi-
tion of the battery is automatically detected and the battery is
charged with the optimum charging current, depending on
battery temperature and voltage.
This gives longer life to the battery and always leaves it fully
charged when kept in the charger for storage.
Note: The charging procedure is only possible when the
battery temperature is within the allowable charging temper-
ature range, see "Technical Data" section.
Meaning of the Indication Elements
Flashing Battery Charge Indicator 2
The charging procedure is signalled by a
flashing battery charge indicator 2.
Continuous Lighting of the Battery Charge Indicator 2
Continuous lighting of the battery
charge indicator 2 indicates that the
battery is fully charged or that the
temperature of the battery is not with-
in the allowable charging temperature range, and cannot be
charged for this reason. The battery is charged as soon as the
allowable charging temperature range is reached.
When the battery is not inserted, continuous lighting of the
battery charge indicator 2 indicates that the mains plug is in-
serted in the socket and that the battery charger is ready for
operation.
Bosch Power Tools
Troubleshooting – Causes and Corrective
10.8 V 14.4 V
18 V
Measures
65
65
80
Cause
90
90
105
Continuous lighting of the battery charge indicator 2
130
160
No charging procedure possible
180
210
Battery not (properly)
inserted
Battery contacts contami-
nated
Battery pack defective
Battery charge indicator 2 does not light up
Mains plug of battery charger
not plugged in (properly)
Socket outlet, mains cable or
battery charger defective
Working Advice
With continuous or several repetitive charging cycles without
interruption, the charger can warm up. This is not meaningful
and does not indicate a technical defect of the battery charger.
A significantly reduced working period after charging indi-
cates that the battery is used and must be replaced.

Maintenance and Service

If the replacement of the supply cord is necessary, this has
to be done by Bosch or an authorized Bosch service agent in
order to avoid a safety hazard.
After-sales Service and Application Service
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. Exploded views and information on spare parts can
also be found under:
www.bosch-pt.com
Bosch's application service team will gladly answer questions
concerning our products and their accessories.
In all correspondence and spare parts orders, please always
include the 10-digit article number given on the nameplate of
the product.
English | 5
Corrective Measure
Properly insert battery into
battery charger
Clean the battery contacts
(e.g. by inserting and remov-
ing the battery several times)
or replace the battery
Replace the battery
Insert mains plug (fully) into
the socket outlet
Check the mains voltage;
have the battery charger
checked by an authorised
after-sales service agent for
Bosch power tools