Commissioning
Connect the mains cable
Note: select the correct cross section and number of wires in the mains cable to suit the on-site voltage and fuse protection.
1
Item
Description
1
Mains cable
2
Mains cable
3
Strain relief
4
Strain relief
5
Terminal strip
Ø
Dismantle the front cover.
Ø
Insert the mains cable (1 / 2) at the rear of the machine.
Ø
Pull out the mains cable at the front.
Ø
For strain relief, secure the mains cable to the mounting plate using a cable tie (3 / 4).
Ø
Observe the connection diagram affixed to the rear of the partition wall for the electrical installation compartment.
Ø
Connect the mains cable wires (5) according to the connection diagram (see } page 59).
Ø
If necessary, install bridges in accordance with the connection diagram and press in firmly using a screwdriver.
Ø
Connect the green-yellow wire to the distributor of the earth wires.
Establishing equipotential bonding
58
2
Note
PTD 702, 703, 704
PTD 701
PTD 701
PTD 702, 703, 704
Ø
Connect the warewasher to the on-site equipotential bonding
system.
Ø
Position of the connecting screw (1) see drawing.