3.7. Logs

3.7.1. Logs
Click the System Logs button to download the system logs, which contains all of the embedded OS activity.
Click the Application Logs button to download the application logs, which contains the activity of the
IOTA-specific software.

3.7.2. Remote Syslog

This facility allows the IOTA to send its system and application logs to remote collection servers. For each
destination, it is possible to specify the type of logs priority and source to send.

3.8. Device Reset

3.8.1. Soft Reset

To reset the password and network parameters, use the following procedure: while the device is
POWERED, press and hold the START/STOP/RESET button for 20 seconds. The procedure is complete
when the LEDs turn green.

3.8.2. Factory Reset

To reset the IOTA to factory settings, use the following procedure: while the device is UNPOWERED, press
and hold the START/STOP/RESET button, connect the power cable, and keep holding the button until the
LEDs turn orange (~20 seconds). Release the button, and wait until the LEDs turn green (~5 minutes).
Note: Resetting the IOTA to factory settings will remove all data stored on the device. The software version
will return to the one installed during production, and thus may need to be updated.