Technical Specifications; Applicability Of Technical Specifications; General Technical Specifications - Siemens SIMATIC IPC RW-545A Operating Instructions Manual

Industrial pc workstation
Table of Contents

Advertisement

Technical specifications

9.1

Applicability of technical specifications

Note
The following technical specifications only apply under the following conditions:
• The device is in good working order.
• The fan cover and filter mat are installed.
• The device is closed.
• The connected I/O devices meet the requirements for the respective area of application
(interference emission according to EN 61000-6-3 / IEC 61000-6-3, immunity to
interference according to EN 61000-6-2 / IEC 61000-6-2).
9.2

General technical specifications

See the note in "Applicability of technical specifications (Page 141)".
Article number
Dimensions
Weight
Supply voltage (U
; AC)
N
Transient overvoltages
Input current
Workstation SIMATIC IPC RW-545A
Operating Instructions, 08/2023, A5E52943278-AA
6AG4104 -6....-.... (for details, refer to the ordering documentation)
481.4 x 176.6 x 446.6 (W× H × D in mm)
Detailed dimensional specifications can be found in "Dimension drawing of the device
(Page 159)".
15 up to 23 kg; depending on the equipment
Power supply unit 550 W; AC:
100 V to 240 V AC (-15%; +10%)
Power supply unit 850 W; (AC):
100 V to 240 V AC (-10%; +10%)
Power supply unit 700 W (2 modules, each 700 W, redundant; AC):
2 × 100 V to 240 V (-15%; +10%)
Device is designed for connection to supply with overvoltage category II
(Transient overvoltages up to 2500 V)
Power supply unit 550 W:
Continuous current at 100 V: ≤ 8 A
Continuous current at 230 V: ≤ 4 A
At startup ≤ 80 A for 3.6 ms
9
141