Technical Specifications; General Specifications - Siemens SIMATIC IPC647D Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC647D:
Table of Contents

Advertisement

Technical specifications

6.1

General specifications

Note
The following technical specifications override the technical specifications in the Operating
Instructions and apply under the following conditions:
• The device is being used as intended and is in proper condition.
• The fan cover and filter mat are installed.
• The front door is closed.
Otherwise, the technical specifications of the device described in the Operating Instructions
apply.
General specifications
Order number
Climatic conditions
Temperature
- During operation
- Storage/transport
Relative humidity
Atmospheric pressure
- During operation
- Storage / transport
Mech. ambient conditions
Vibration
- Operation
- Storage/transport
Resistance to shock
- Operation
- Storage/transport
Special features
Quality assurance
Drives (for configuration details, refer to the order documentation)
Hard disk drive
1
SIMATIC IPC647D/847D Hardware RAID Configuration
Compact Operating Instructions, 08/2014, A5E34655907-AA
1
1
Restrictions when HDDs are mounted in removable drive bays:
mechanical stress must be safely excluded.
See the order documents
Tested to:
IEC 60068-2-2, IEC 60068-2-1, IEC 60068-2-14
0 °C to +35 °C
Gradient: Max. 10 °C/h, no condensation
- 20°C to + 60°C
Gradient: Max. 20 °C/h, no condensation
Tested to IEC 60068-2-78, IEC 60068-2-30
1080 to 795 hPa
(corresponds to an altitude of -1000 to 2000 m)
1080 to 660 hPa
(corresponds to an altitude of -1000 to 3500 m)
Tested to IEC 60068-2-6, 10 cycles
5 to 9 Hz: 3.5 mm, 9 to 500 Hz: 9.8 m/s
Tested to IEC 60068-2-27, IEC 60068-2-29
Half-sine: 250 m/s
, 6 ms, 1000 shocks per axis
2
to ISO 9001
3.5" SAS 6 Gbps, size: 1000 GB
NCQ (Native Command Queuing) is supported.
6
2
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ipc847d

Table of Contents