Setting Up PASS/FAIL Analysis
Select acceptance criteria
Inspection (Probe)
1.
Open the INSPECT (Probe) application.
2.
Press
MENU.
3.
Select PROFILE (choose desired PROFILE from list).
4.
Select TIP (choose from list).
Inspection (PCM)
1.
Open the INSPECT (PCM) application.
2.
Press
MENU.
3.
Select PROFILE (choose desired PROFILE from list).
Set up OPM PASS/FAIL thresholds
Wavelengths are measured in dBm.
I
1.
Open the POWER METER application.
2.
Select MORE... > EDIT WAVELENGTH TABLE.
3.
Select a wavelength from the list.
4.
Press
MENU.
5.
Select ENTER LIMIT.
6.
Enter you desired limit value (measured in dBm) using the
numeric keypad.
7.
Press OK.
8.
Repeat steps 4–7 for all desired OPM wavelengths.
9.
Check the boxes for only the wavelengths you want to use.