Installation

Install Accessories

Install Monitoring Accessories
Install the following accessory to monitor equipment
performance.
Leak Sensor: Monitors for leaks in the pump due
to diaphragm rupture. Automatically stops pump
operation and triggers the LED Indicator if a leak is
detected. Not provided with the equipment.
Accessory kits are available (purchase separately).
See Related Manuals, page 2.
NOTICE
To avoid pump damage, install a leak sensor to
detect leaks in the equipment due to diaphragm
rupture.
Install Fluid Line Accessories
Install the following accessories in the order shown in
F
. 3 and F
. 4, using adapters as needed.
IG
IG
Fluid drain valve (G): Required. Relieves fluid
pressure in the system.
Fluid shutoff valve (H): Shuts off fluid flow.
Fluid pressure gauge (M): For more precise
adjustment of the fluid pressure.
Fluid outlet line (J): Required. To dispense fluid.
Fluid supply line (F): Required. Enables the
equipment to draw fluid from a container.
Install Fluid Leak Line Accessories
If a leak sensor is not installed in the pump and the
diaphragm ruptures, the equipment will fill with fluid
or fluid will drain into the work area. To avoid injury
from leaking fluid, toxic fluid, toxic fumes, splashing
fluid, or hot fluid, install fluid drain lines to route fluid
leaks due to diaphragm rupture.
NOTICE
To avoid pump damage due to diaphragm rupture,
install a leak sensor to detect leaks in the equipment
and automatically stop pump operation. See Install
Monitoring Accessories, page 14.
14
If a leak sensor is not installed in the pump, install the
following accessory as shown in F
as needed.
NOTE: To monitor for leaks in the pump due to
diaphragm rupture, install a leak sensor. See Install
Monitoring Accessories, page 14.
Fluid Leak line (L2): Routes fluid to a drain location
if fluid leaks due to diaphragm rupture.
1. Remove the plugs (if applicable) in the diaphragm
access ports (L).
2. Install conductive, flexible fluid leak lines (L2) to the
diaphragm access ports (L).
3. Route the fluid leak lines (L2) to a grounded end
container (L3) to catch leaking fluid. Follow local
codes and regulations for grounding.
NOTE: For Models in Explosive Atmospheres or
Hazardous (Classified) Locations): Ensure the end
container is grounded and located in a
non-explosive or non-hazardous environment.
Diaphragm access ports must not be open in
hazardous locations. Ports must have installed
either plugs 814-0346 (as shipped from the factory),
or leak sensor kit 814-0295.
L
L
F
. 6: Typical Installation of Fluid Leak Lines (Ordinary
IG
Locations)
. 6, using adapters
IG
L2
L3
813-0525B