HP 5334B Service Manual page 62

Universal counter
Hide thumbs Also See for 5334B:
Table of Contents

Advertisement

Table
4-4.
HP-ZB Operational Verification
Program Listing (Continued)
3590 WAIT 1000
'
3600 OUTPUT A ;"BS1"
3610 GOSUB 8540
3620 OUTPUT A ;"BS0 B X I "
3630 GOSUB 8540
3640 OUTPUT A ;"BX0 B A l "
3650 GOSUB 8540
3660 OUTPUT A ;"BA0 BZ1"
3670 GOSUB 8540
3680 OUTPUT A ;"BZ0 I N AU0
3690 CLEAR
3700 DISP "The 5334A/B i s i n t h e READ PEAKS Bmode."
3710 DISP
3720 OUTPUT A ; " I N FN15 "
3730 DISP D$;"shows ' 0 . 0 0
0 . 0 0 b ' . "
3740 DISP
3750 DISP
F$
3760 PAUSE
3770 CLEAR
3780 OUTPUT A ; " I N AU0"
3790 GOT0 7960
3800 !
3810 ! CHECKPOINT 6
3820 I $ = "
T r i g g e r L e v e l s
3830 S=6
3840 GOSUB 7810
3850 DISP E $ ; " t h e 5334A/B0
3860 DISP " w i l l be programmed t o t h e
3870 DISP
3880 DISP "-2.34
1.56 L "
3890 DISP
3900 PAUSE
391 0 REMOTE A
3920 OUTPUT 6 ;"TR0 SE0"
3930 OUTPUT A ;"AT-2.34
BT+1.56
"
3940 OUTPUT A ;"TRI FN13"
3950 CLEAR
3960 DISP D$
3970 DISP " r e a d s '-2.34
1.56 L ' . "
3980 DISP
3990 DISP
F$
4000 PPlUSE
401 0 CLEAR
4020 DISP " P r e s s RESET/LOCAL."
4030 DISP " P r e s s READ LEVELS 4 t i m e s . "
4040 DISP
4050 DISP " T h i s sequence a l l o w s t h e t r i g g e r l e v e l c o n t r o l t o r e t u r n t o t h e
f r o n t
p a n e l .
"
4060 DISP
4070 DISP " A d j u s t t h e A and B LEVEL knobs
f o r
a
d i f f e r e n t l e v e l r e a d i n g . "
4080 DISP E5;"check t h a t "
t r i g g e r l e v e l s b e l o w . "
HP 5334B
- Senice
Manual
4-52

Advertisement

Table of Contents
loading