HP 5334B Service Manual page 204

Universal counter
Hide thumbs Also See for 5334B:
Table of Contents

Advertisement

8-469.
SIGNATURE ANALYSIS SETUP
#2
To perform sipature analysis for Setup
#Z,
proceed as follows:
a. Switch off power to the Counter.
b. Attach the test pod leads of the signature a n a l p r as fouows:
STISPIESTART: 1701, pin 6
QUAU/STOP: J701, pio 1 (VCC)
CLOCK: J701, pin 7 (CLK)
GM):
J701, pin 9
(GND)
c.
Set
the signature analyzer as foIlow.
FUNCTION: QUAL
CLOCK: falling edge
START: rising edge
STOP: rising edge
QUAL: high level
d. Power up the Counter and verify the signatures shown in Figure
8-16.
HP 5334B
-
Service Manual
8-04

Advertisement

Table of Contents
loading

Table of Contents