piston position by the handle or a flash starting attempt, it can be completely the roost risk for
long time.
Consider that on the marine engines employed for the nautical generating sets, there are no
critical connections between cooling water and fire zone, so in case of some gasket breakage
there is water sprayed out of the engine, around it into the hood and never water entering into
the piston or the sump zone.
Our technical staff is in any case at customer's disposal for additional suggestions or solving
out of standard cases for getting the complete satisfaction result, that can be always reached
putting more attention on the plant, or adding special accessories like a dry exhaust pipe and
similar.