Communication Connection - Redx RX Series User Manual

Hybrid inverter
Hide thumbs Also See for RX Series:
Table of Contents

Advertisement

5.7

Communication Connection

1
11
21
1
A
3
Figure 5.7.2 - RX-7000HY/5000HY Communication connector
Rev 20230601
Pin
Group
Definition
A1
Dry contact 1 Public
1
A2
Dry contact 1 open
2
A3
Dry contact 1 close
3
Dry contact 2 public
10
A4
4
Dry contact 2 open
A5
5
Dry contact 2 close
A6
6
20
/
7
B1
485D+
8
30
485D-
B2
9
B3
GND
10
BMS_CAML
C1
11
C2
BMS_CANH
12
C3
GND
13
C4
BMS_485A+
14
BMS_485A-
C5
15
B
RX - 7000HY/5000HY
Pin
Group
B8
16
B7
17
18
B6
19
B5
20
B4
Negative Input For Switch
21
D1
/
Positive Input For Switch
D2
22
23
D3
24
D4
25
D5
26
D6
27
D7
28
D8
29
D9
30
D10
Page 24 of 41