Page 1
Document #2002-XTIPIN COMPLETE SETUP AND PROGRAMMING MANUAL XT-IP 630 PANELS A Videofied CMA/XMB/XMA/WMB Alphanumeric Keypad or Frontel TMT2 is required for programming and maintenance XMB/XMA 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 877-206-5800...
2013/01/18 Ed 1 Setup and Programming manual for XTIP series Regulatory Information for USA and Canada FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC authorization to operate this equipment. FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
If you are currently using TMT Installer to program the system you can now take still pictures from each MotionViewer using the software. See TMT Installer Users Manual available on http://support.videofied.com 4) Once you have everything mounted, arm the system and trip one MotionViewer at a time. Make sure you stand in front of each MotionViewer for 10 seconds so the central station has some video to look at.
Setup and Programming manual for XTIP series Introduction: Description: The XTIP control panel is a Videofied wireless, battery operated hybrid alarm system. It is designed for residential, small business and commercial security applications. The XTIP provides integrated Video Verification and features dual communication paths: Ethernet and 2G3G (3G or less).
Page 6
2013/01/18 Ed 1 Setup and Programming manual for XTIP series SETUP MANUAL FOR XTIP SERIES 3G PANEL *THIS SYSTEM REQUIRES A CMA/XMB/XMA/WMB or TMT2 INSTALLER SOFTWARE FOR PROGRAMMING* **TO TRANSMIT ALARMS AND VIDEO VIA ETHERNET, THE SYSTEM REQUIRES AN EXTERNAL POWER SUPPLY WITH 4 ALKALINE BATTERIES FOR BACK-UP (PP4)** XT Initial Programming Open the Control Panel Using a #1 Phillips screwdriver, remove...
Page 7
2013/01/18 Ed 1 Setup and Programming manual for XTIP series *The SIM card must NOT be inserted or removed while the panel is powered* Install the SIM card Slide SIM card into the slot. Make sure it is aligned correctly. The SIM card is not required if you plan to use Ethernet only.
Page 8
2013/01/18 Ed 1 Setup and Programming manual for XTIP series Powering the Panel **THE CONTROL PANEL MUST BE CONNECTED TO AN EXTERAL POWER SUPPLY WHEN ETHERNET FEATURE IS ACTIVE** Option 1: PP1 Option 2 4 x LSH20 SAFT Lithium D-Cell 4 x E95VP Alkaline D-Cell + 12v 2amp DC Class 2 power supply (not supplied) Used for Standalone or Xtender mode without...
Page 9
2013/01/18 Ed 1 Setup and Programming manual for XTIP series XTIP Programming Reset the XTIP Panel: Press and hold programming button ( ) for 10sec until the Indicator LED blinks twice Press and instantly release the programming button ( The indicator LED will blink once. The panel is now in ‘Learn Mode’...
Page 14
2013/01/18 Ed 1 Setup and Programming manual for XTIP series ETHERNET PARAMETERS DHCP: ENABLE OR DISABLE DISABLE PANEL IP • These parameters are not necessary if you choose IP MASK DHCP ENABLE ENABLE • These parameters are the local network parameters. It’s necessary to configure all these parameters if GATEWAY DHCP is disabled.
2013/01/18 Ed 1 Setup and Programming manual for XTIP series Device Installation DCV651 – Outdoor MotionViewer / BR651 Outdoor Badge Reader Place batteries in Device. Wait for LED to turn on. Press and release the programming button. DCV601 – Indoor MotionViewer / ITR601 – Indoor Blind PIR Place batteries in device.
2013/01/18 Ed 1 Setup and Programming manual for XTIP series How to Disable/Enable Monitoring Disabling monitoring can be a useful tool in many situations. Before mounting devices and moving the panel to find a good GPRS / 3G level, disabling monitoring will ensure that you will have access to programming and that unnecessary signals are not sent to the monitoring station.
2013/01/18 Ed 1 Setup and Programming manual for XTIP series Entering a Badge or Access Code for Arming/Disarming After Initial programming has been completed, you are not able to arm and disarm the system until you enter a user code or badge (the installer code cannot arm and disarm the system). Codes can be 4-6 digits and the 4 digit must be 2 values higher or lower than any other code on the system: Example: User code 1234, next code cannot be 1235, 1236, 1233, or 1232 –...
2013/01/18 Ed 1 Setup and Programming manual for XTIP series Access level Definition & rights Stand by level LVL1 Restricted USER level where it is only possible to arm/disarm the system. LVL2 USER level where it is possible to arm/disarm the system, check the event log, test the devices.
2013/01/18 Ed 1 Setup and Programming manual for XTIP series ETHERNET Parameters: nging Siren Options To configure or modify Ethernet Parameters, go to: CONFIGURATION (level 4) + [YES/OK] >> GENERAL PARAMETERS + [YES/OK] >> ETHERNET + After initial programming has been completed any sounder on the system will be enabled by default, [YES/OK] this includes the sounder on the Keypad and Badge Reader.
2013/01/18 Ed 1 Setup and Programming manual for XTIP series GPRS / 3G for deployment of panel Before the system is mounted you will need to check the GPRS / 3G level to make sure it is adequate. If the level is 3/5 or better you can mount the control panel in that location.
How to test RF for deployment of devices Running the RF test during the mounting of devices is key to a successful Videofied installation. This test will ensure that all devices have adequate communication with the control panel. All Videofied devices are bi-directional which allows the system to ping the device and expect a response.
Setup and Programming manual for XTIP series Arming Input Wiring Diagram When in the ‘Arm From Host’ mode the Videofied system will only arm and disarm when 9-12v is supplied and sustained. When both arming inputs are supplied voltage at the same time the Videofied Keypad display will show ‘SYSTEM ARMED.
2013/01/18 Ed 1 Setup and Programming manual for XTIP series How to test to the dispatch center Testing to the dispatch is done twice during installation. Once while you are programming the system and then again once the installation has been completely finished. Although both will use the same steps the initial test will be just confirmation using one device to verify the programming.
2013/01/18 Ed 1 Setup and Programming manual for XTIP series How to mount the XTIP How to Mount the Control Panel? Fix the back casing on the wall with 3 screws (n) 27 | P a g e 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110...
2013/01/18 Ed 1 Setup and Programming manual for XTIP series General Programmable Input Configuration 28 | P a g e 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110...
Page 29
2013/01/18 Ed 1 Setup and Programming manual for XTIP series 29 | P a g e 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110...
Page 30
2013/01/18 Ed 1 Setup and Programming manual for XTIP series 30 | P a g e 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110...
2013/01/18 Ed 1 Setup and Programming manual for XTIP series General Programmable Output Configuration 31 | P a g e 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110...
Page 32
2013/01/18 Ed 1 Setup and Programming manual for XTIP series 32 | P a g e 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110...
Page 33
2013/01/18 Ed 1 Setup and Programming manual for XTIP series 33 | P a g e 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110...
2013/01/18 Ed 1 Setup and Programming manual for XTIP series Scheduling Configuration 34 | P a g e 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110...
Page 35
2013/01/18 Ed 1 Setup and Programming manual for XTIP series 35 | P a g e 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110...
Page 36
2013/01/18 Ed 1 Setup and Programming manual for XTIP series 36 | P a g e 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110...
Good communication between the MotionViewers and the Control Panel is key to getting successful video to the monitoring station. During mounting of any device on your Videofied system you must run the Radio Range/Device Locating test to ensure that the mounting location is with-in range of the Control Panel.
Page 38
2013/01/18 Ed 1 Setup and Programming manual for XTIP series Monitoring Station is not getting any signals: Communication between the Control Panel and the Monitoring Station is either over the Ethernet Connection or GPRS / 3G side of the GSM cellular network. ¾...
Page 39
2013/01/18 Ed 1 Setup and Programming manual for XTIP series Unable to record device or getting ‘Pairing Failure’ error This usually occurs when the device still has a pairing key from a previous system or setup. To perform a pairing key override: 1.
2013/01/18 Ed 1 Setup and Programming manual for XTIP series XTIP -SERIES ‘AFTER INITIAL PROGRAMMING’ FLOW CHART Parameters are only available in Access Level 4 40 | P a g e 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110...
Page 41
2013/01/18 Ed 1 Setup and Programming manual for XTIP series 41 | P a g e 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110...
2013/01/18 Ed 1 Setup and Programming manual for XTIP series Addendum 1. LSH20 Control Panel Batteries: 2. LS14500 Peripheral Batteries: Excludes SE601 and SE651 3. Lithium Battery Storage: 42 | P a g e 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110...
Page 43
2013/01/18 Ed 1 Setup and Programming manual for XTIP series 4. Finding Manufacture Week and Year: The Manufacture week and year can be found in the serial number of the device/control panel. The second sets of 4 numbers in the serial number are WWYY. ####0411######## = Which shows that this device was manufactured in the 4 week of 2011.
Need help?
Do you have a question about the XT-IP 630 and is the answer not in the manual?
Questions and answers