INSTALLATION MANUAL
INS8719
ATTENTION INSTALLERS:
These instructions must be
left with the customer
www.insigniarange.com
CHECK ALL CONTENTS BEFORE BUILD COMMENCES. NO RETURNS CAN BE MADE
ONCE THE BUILD HAS STARTED AS IT IS DEEMED ACCEPTANCE OF PRODUCT!
WARRANTY REG NO: __________________________
To claim your full 5 year warranty, register your shower within 90 days of delivery at: www.insigniarange.co.uk/
warrantyreg.aspx. Standard 12 month warranty applies if outside this time period.
Last Modified: 20/06/2018
www.insigniarange.co.uk
30 Day Technical Support:
(NOTE: This service is only available to customers from the day of delivery,
please have your supplier's details and your postcode to hand before calling)
Replacements Parts:
inside of your warranty contact:
www.insigniarange.co.uk/customerService.aspx
Spares/Replacements Parts:
outside of your warranty
contact 0844 800 3069
01908 226545

Advertisement

loading

Summary of Contents for Insignia INS8719

  • Page 1 INSTALLATION MANUAL 30 Day Technical Support: 01908 226545 INS8719 (NOTE: This service is only available to customers from the day of delivery, please have your supplier’s details and your postcode to hand before calling) Replacements Parts: inside of your warranty contact: www.insigniarange.co.uk/customerService.aspx...
  • Page 2 www.insigniarange.com Last Modified: 20/06/2018 Contents Introduction Electrical Requirements What’s In The Boxes? Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Control Panel Connections Sealing and Water Testing Control Panel Instructions Help Book Information Part list...
  • Page 3 Last Modified: 20/06/2018 Thank you for your recent purchase of an Insignia shower. Please read this booklet with great care to ensure you get the best out of your build and have a shower that will last for many years to come! Like everything, in order to obtain a first class product that will serve you well for many years, the effort and correctness put into the assembly will reflect in the quality of your finish.
  • Page 4 DURING BUILD, LIKE ALL SHOWERS CORRECT SEALING IS IMPERATIVE. If you are using Insignia’s RubberGum, please ensure the product does not come in contact with your silicone as this will cause the RubberGum to fail and will not adhere as intended.
  • Page 5 www.insigniarange.com Last Modified: 20/06/2018 TOTAL ELECTRICAL REQUIREMENTS Voltage Rating 220 -240AC Frequency Rating 50HZ Power Rating Your electrical contractor should understand ALL legal requirements of connection before undertaking any work or installation. UNDER NO CIRCUMSTANCES UNDERTAKE THIS YOURSELF!!! Note for electrician. This product comes with 3 amp plug. We leave it this way for you to connect this your own way due to continued additions to current regulations.
  • Page 6 www.insigniarange.com Last Modified: 20/06/2018 Tool Requirements None Supplied Scissors Stanley Blade Silicone Gun Spirit Level Tape Measure Philips Screwdriver Electric Drill PREVENT INJURIES! This product may contain sharp edges. Assemble using gloves. Safety Gloves Safety Glasses Use safety glasses when handling glass or drilling. Adhesive Requirements Bacteria Resistant Sanitary Silicone - (for vertical joints) RubberGum...
  • Page 7 2x fixed glass In addition to above you will have all the required internal accessories to complete the shower. VERY IMPORTANT Have you got everything? If not please contact the Insignia Support Line on 01908 226545. Remember NEVER book your tradesman until everything has arrived, been checked and is present.
  • Page 8 Last Modified: 20/06/2018 Insignia Screw Pack Product Code Description Quantity SP097 Door Handles SP276 Twin Wheels Non Push (Black/ Chrome) SP276A Twin Wheels — Push Button (Black/ Chrome) ST12 12mm Screws ST14 14mm Screws ST16 16mm Screws ST18 18mm Screws...
  • Page 9 www.insigniarange.com Last Modified: 20/06/2018 Pressure Requirements from your house supply We recommend a bar pressure between 2.5 and 3.4 BAR. If you have a combi boiler system no problem should be experienced. If you have a gravity feed older type installation (hot water tank type usually less than 1 bar) you will almost certainly need a pump.
  • Page 10 www.insigniarange.com Last Modified: 20/06/2018...
  • Page 11 www.insigniarange.com Last Modified: 20/06/2018 Whilst the next steps show you how to assemble your shower we want to make sure you have a correct build to ensure you get a trouble free shower. Therefore our advice is to follow the instructions and perform a dry run to ensure you are confident with the build and you understand fully how the unit is assembled.
  • Page 12 www.insigniarange.com Last Modified: 20/06/2018 Step 1 Align the 2 back panels with the central column and fix together using the ST20 nuts and bolts. Once you are happy with the alignment, remove the panels and run a bead silicone up the sides and Rubbergum along the bottom of the column and the back panels yet DO NOT fix them to the tray until STEP 5.
  • Page 13 Please note the ‘U’ shaped channel is meant to face inwards to allow the glass to fit correctly. (wider rail with Insignia logo at the top) PLEASE NOTE The screw head needs to bypass the OUTER hole.
  • Page 14 www.insigniarange.com Last Modified: 20/06/2018 Step 3 Step 3 (continued) The inner uprights have a ‘T’ shaped slot in which you have a Now attach your inner uprights to your front fixed glass panels by inserting these over seal, perfectly shaped to slot in here. Insert the seal on both the thin rubber seals as shown by the arrows in the image.
  • Page 15 www.insigniarange.com Last Modified: 20/06/2018 Step 4 One the fixed glass and uprights are in place you will have 4 push style seals to insert. ALL seals go on the outside of the shower. The two thicker seals will go between the fixed glass and the inside uprights. The two thinner seals will go between the outside uprights and the fixed glass.
  • Page 16 www.insigniarange.com Last Modified: 20/06/2018 Step 5 Now attach your inner uprights to your front fixed glass panels by inserting these over the thin rubber seals as shown by the arrows in the image. Next screw the inner uprights to your curved rails using the ST16 screws for the top and ST25 screws for the bottom.
  • Page 17 www.insigniarange.com Last Modified: 20/06/2018 Step 7 Align the roof with your shower walls and using the ST14 screws and SW9 washers fix the back walls to the roof by screwing upwards from the rear of the shower and repeat this process to fix to the tray as indicated in the images...
  • Page 18 www.insigniarange.com Last Modified: 20/06/2018 Step 8 Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels are at their lowest position and hang on the inner curved rails with the wheels facing the outside of the glass. Please note the push button wheels are for the bottom.
  • Page 19 www.insigniarange.com Last Modified: 20/06/2018 Accessory Installation Please Note Ensure all backing film on the rear of the glass panels are pierced through the existing glass holes with a knife to provide an efficient smooth fitting and location of the accessories. We recommend using a screwdriver on the smaller holes.
  • Page 20 www.insigniarange.com Last Modified: 20/06/2018 Monsoon Head Attach the grey hosing from your valve to the 90 degree push fit elbow. Secure in place using the jubilee clips found on the grey hosing. You should have one for each end of the hose. Attach the grey hose from your valve to the inner black tube using PTFE tape (please note this only needs to be hand tight. Over tightening will snap/damage the inner black tube) Handle Ensuring that the inner thread is protruding out from the handle far enough, place the handle on the outside of the door and secure by tightening the inner chrome knob to...
  • Page 21 Connect the corresponding hoses to the rear of the valve as shown. Device output may differ from the image. Please refer to your outer chrome faceplate inside your Insignia shower as a reference point. IF YOUR DIAL DOES NOT CORRESPOND TO THE APPROPRIATE DEVICE: Turn on your water to the shower and note which output the water exits from then turn off the water and swap over the relevant hose.
  • Page 22 www.insigniarange.com Last Modified: 20/06/2018 Electric Box Connections Electric Box Connections Connect the cables below to the corresponding devices on the shower Connect the cables below to the corresponding devices on the shower Roof Light Speaker Antenna Speaker...
  • Page 23 www.insigniarange.com Last Modified: 20/06/2018 Silicone Seal (vertical joints) RubberGum (horizontal joints) TESTING FOR WATER LEAKS LEAVE THE SHOWER 24 HOURS AFTER BUILD TO ALLOW SEALANT TO CURE AND ENSURE THE SHOWER IS AWAY FROM ITS FINAL POSITION TO ALLOW REAR VIEWING Ensure all connections are tight and sealed including the waste, body jets and steam outlet (model dependent) on your shower.
  • Page 24 When the Bluetooth is activated this will skip to the next song in your playlist. To see our tutorial videos for operating this control panel’s features, please search for “Insignia Showers” on YouTube and find our “SUN Control Panel” Playlist, or you can...
  • Page 25 Last Modified: 20/06/2018 Need Help? If so then simply download Insignia’s free comprehensive help and troubleshooting brochure now! Simply visit: www.insigniarange.co.uk/help.aspx...
  • Page 26 www.insigniarange.com Last Modified: 20/06/2018 Parts List Internal Items Framework SP036 Speaker Part Code Part Description Part Code Part Description SP228 Speaker cover INS8721.1-8 Top and bottom rails SP063 Monsoon Shower head INS8721.1-1 Tray SP145 Control Panel SP243 Fold down seat INS8721.1-2 Blank roof SP152...
  • Page 27 All images are registered with ImageTraker Insignia™ is a registered trademark of Maclean International Ltd All images are subject to copyright. Images may not be used in any way shape or form with out written permission from Maclean International Ltd. Images are NOT permitted...