INSTALLATION MANUAL
INS8058.1R
ATTENTION INSTALLERS:
These instructions must be
left with the customer
insigniarange.com
CHECK ALL CONTENTS BEFORE BUILD COMMENCES. NO RETURNS CAN BE MADE
ONCE THE BUILD HAS STARTED AS IT IS DEEMED ACCEPTANCE OF PRODUCT!
WARRANTY REG NO: __________________________
To claim your full 5 year warranty, register your shower within 90 days of delivery at: www.insigniarange.co.uk/
warrantyreg.aspx. Standard 12 month warranty applies if outside this time period.
Last Modified: 10/10/2019
www.insigniarange.co.uk
30 Day Technical Support:
(NOTE: This service is only available to customers from the day of delivery,
please have your supplier's details and your postcode to hand before calling)
Replacements Parts:
inside of your warranty contact:
www.insigniarange.co.uk/customerService.aspx
Spares/Replacements Parts:
outside of your warranty
contact 0844 800 3069
01908 226545

Advertisement

loading

Summary of Contents for Insignia INS8058.1R

  • Page 1 INSTALLATION MANUAL 30 Day Technical Support: 01908 226545 INS8058.1R (NOTE: This service is only available to customers from the day of delivery, please have your supplier’s details and your postcode to hand before calling) Replacements Parts: inside of your warranty contact: www.insigniarange.co.uk/customerService.aspx...
  • Page 2 Last Modified: 10/10/2019 Thank you for your recent purchase of an Insignia shower. Please read this booklet with great care to ensure you get the best out of your build and have a shower that will last for many years to come!
  • Page 3: Table Of Contents

    insigniarange.com Last Modified: 10/10/2019 Contents Introduction Electrical Requirements What’s In The Boxes? Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Electric Box Connections Steam Generator Connections Sealing and Water Testing SUN Control Panel Instructions Help Book Information Parts list Bathroom Electrical Zones WEEE Compliance Statement...
  • Page 4 DURING BUILD, LIKE ALL SHOWERS CORRECT SEALING IS IMPERATIVE. If you are using Insignia’s RubberGum, please ensure the product does not come in contact with your silicone as this will cause the RubberGum to fail and will not adhere as intended.
  • Page 5 insigniarange.com Last Modified: 10/10/2019 TOTAL ELECTRICAL REQUIREMENTS Voltage Rating 220 -240AC Frequency Rating 50HZ Power Rating 2.8KW Your electrical contractor should understand ALL legal requirements of connection before undertaking any work or installation. UNDER NO CIRCUMSTANCES UNDERTAKE THIS YOURSELF!!! Note for electrician. This product comes with 13 amp plug(s) fitted with an RCD unit. We leave it this way for you to connect this your own way due to continued additions to current regulations.
  • Page 6 insigniarange.com Last Modified: 10/10/2019 Tool Requirements None Supplied Scissors Stanley Blade Silicone Gun Spirit Level Tape Measure Philips Screwdriver Electric Drill PREVENT INJURIES! This product may contain sharp edges. Assemble using gloves. Safety Gloves Safety Glasses Use safety glasses when handling glass or drilling. Adhesive Requirements Bacteria Resistant Sanitary Silicone - (for vertical joints) Plumbers Mait (for waste joints)
  • Page 7: What's In The Boxes

    insigniarange.com Last Modified: 10/10/2019 Whilst the next steps show you how to assemble your shower we want to make sure you have a correct build to ensure you get a trouble free shower. Therefore our advice is to follow the instructions and perform a dry run to ensure you are confident with the build and you understand fully how the unit is assembled. When we use the word “DRY RUN”...
  • Page 8 Drill Piece VERY IMPORTANT VERY IMPORTANT Have you got everything? If not please contact the Insignia Support Line on 01908 226545. Remember Have you got everything? If not please contact the Insignia Support Line on 01908 226545. Remember NEVER NEVER...
  • Page 9 insigniarange.com Last Modified: 10/10/2019 Pressure Requirements from your house supply We recommend a bar pressure between 2.5 and 3.4 BAR. If you have a combi boiler system no problem should be experienced. If you have a gravity feed older type installation (hot water tank type usually less than 1 bar) you will almost certainly need a pump.
  • Page 10 insigniarange.com Last Modified: 10/10/2019...
  • Page 11 insigniarange.com Last Modified: 10/10/2019 TO START Make sure you have a clear space, remember when finished and in place you need access to check your build and able to pull the shower out for servicing or should you have the need to replace anything! Take the shower tub and remove all the protective wrapping and fit the waste.
  • Page 12 insigniarange.com Last Modified: 10/10/2019 Step 2 (please note, if your column has a rubber seal at the bottom , take the rubber off and apply silicone inside the rubber and replace) Step 2 Again, Once you have completed a dry run and are happy, Then continue to ap- ply the silicone to the specified area of the control column and place next to the an- gled back glass panel and fix together using the ST20 screws.
  • Page 13 insigniarange.com Last Modified: 10/10/2019 Step 4 Now lock the front angled glass panel to the side glass panel by following the position shown in the image marked “1” Once you have met the back panel inside the front upright as per the close up image walk the panel around to the position shown in the image marked “2”...
  • Page 14 insigniarange.com Last Modified: 10/10/2019 Step 6 Lower the top curved rail into position and screw from the rear side as per the image using the ST35 screws. Fix the front of the top curved rail onto the upright of the front fixed angled glass. Please note in order to do this you will need to slide up the front fixed panel roughly 3 inches to expose the screw holes.
  • Page 15 insigniarange.com Last Modified: 10/10/2019 Step 8 Step 8 Now apply silicone to the bottom of the remaining curved rail and place into position as shown in the diagram and fix this into place using the ST35 screws and ST14 screws Please note that when drilling the holes to take the screws this is at a depth no deeper than 5mm.
  • Page 16 insigniarange.com Last Modified: 10/10/2019 Step 10 Insert remaining upright to the left of the curved glass panel. Drill and screw this into position using the ST20 screws and once fixed slide the flat rubber glass seal into this newly fitted upright on the inside (as of the green line in the image) Please Note: ensure you drill no deeper than 5mm.
  • Page 17 insigniarange.com Last Modified: 10/10/2019 Step 12 Step 12 Pierce through the holes using a screwdriver to show pre-cut holes in the glass as indicated in the image. Now repeat the process from step 11 to secure the roof to the glass panels Step 13 Step 13...
  • Page 18 insigniarange.com Last Modified: 10/10/2019 Accessory Installation Please Note Ensure all grey backing film on the rear of the glass panels are pierced through the existing glass holes with a knife to provide an efficient smooth fitting and location of the accessories.
  • Page 19 insigniarange.com Last Modified: 10/10/2019 Hand Shower Attach the chrome riser bar to the glass wall ensuring the water inlet is inserted through the lower large hole and hand tightened from the rear side. Now tighten the chrome shower holder ensuring that this will take the hand shower itself without falling (please note over tightening will prevent the holder from sliding up and down) Thermostatic Probe...
  • Page 20 insigniarange.com Last Modified: 10/10/2019 Door Seals Magnetic Seal: Push the magnetic door seal on the handle side of the glass door ensuring this is tightly fitted. Rear Door Seal: Place the rear door seal on the opposite side to the magnetic strip ensuring the flap is facing the fixed glass panel Handle Ensuring that the inner thread is protruding out from the handle far enough, place...
  • Page 21 insigniarange.com Last Modified: 10/10/2019 AMI Install Remove white blanking caps from column (if supplied) AMI Box Contents Product Code Description Quantity AMI01 Jubilee Clip AMI02 PVC Hose (1 metre) AMI03 AMI Essence Filler AMI04 Solenoid AMI05 Brass T-Piece Connector AMI06 Straight Pipe Connector AMI07 Battery Box (Inc Velcro)
  • Page 22 Monsoon Shower Hand Shower Device output may differ from the image. Please refer to your outer chrome faceplate inside your Insignia shower as a reference point. Body Jets Bath Filler IF YOUR DIAL DOES NOT CORRESPOND TO THE APPROPRIATE DEVICE: Turn on your water to the shower and note which output the water exits from then turn off the water and swap over the relevant hose.
  • Page 23: Electric Box Connections

    insigniarange.com Last Modified: 10/10/2019 Electric Box Connections Connect the cables below to the corresponding devices on the shower Roof Light Antenna Speaker Speaker Thermostatic probe Power Supply...
  • Page 24: Steam Generator Connections

    insigniarange.com Last Modified: 10/10/2019 Steam Generator Connections The steam generator has 3 connections. Steam Outlet: Connect the white insulated hose to the tri-jet steam system within your shower. Make sure these are fitted in the correct position as they are only attached for transportation reasons only.
  • Page 25 insigniarange.com Last Modified: 10/10/2019 Roof Lights The roof lights come packed in with your accessories and need to be inserted on site. On top of the roof there are 24 nuts, which simply need tightening by hand. Once this is done, the lights simply push onto the fitting.
  • Page 26 insigniarange.com Last Modified: 10/10/2019 Safety precautions Never leave children unattended in the shower or bath. Never bath children (under 12) using whirlpool function if fitted. Regulate the temperature of water before showering Never allow children to use the steam function. This function is for ADULTS ONLY. Always be aware of the steam outlet pod position.
  • Page 27 insigniarange.com Last Modified: 10/10/2019 Silicone Seal (vertical joints) shown in red on the inside of the shower TESTING FOR WATER LEAKS LEAVE THE SHOWER 24 HOURS AFTER BUILD TO ALLOW SEALANT TO CURE AND ENSURE THE SHOWER IS AWAY FROM ITS FINAL POSITION TO ALLOW REAR VIEWING Ensure all connections are tight and sealed including the waste, body jets and steam outlet (model dependent) on your shower.
  • Page 28 10 minutes. After this the screen will power off. To see our tutorial videos for operating this control panel’s features, please search for “Insignia Showers” on YouTube and find our “SUN Control Panel” Playlist, or you can...
  • Page 29 insigniarange.com Last Modified: 10/10/2019 Control Panel Instructions Connecting to Bluetooth Step 2 Step 1 Then simply go on your device and To connect a device via pair up with the shower which should Bluetooth, press the music be shown as “INS”. Once this is function button twice (which complete you will hear a beep to looks like a musical note) the...
  • Page 30 Last Modified: 10/10/2019 Need Help? If so then simply download Insignia’s free comprehensive help and troubleshooting brochure now! Simply visit: www.insigniarange.co.uk/help.aspx...
  • Page 31: Parts List

    Last Modified: 10/10/2019 Parts List Internal Items Framework Part Code Part Description SP117 Insignia Control panel Part Code Part Description SP027 Monsoon Shower head SP227 Microphone style hand INS8058R-4 Column (Blank) shower SP078 Ozone Module (for Steam INS8058R-7 Top & Bottom Door Rail...
  • Page 32: Bathroom Electrical Zones

    insigniarange.com Last Modified: 10/10/2019 Bathroom Electrical Zones...
  • Page 33 insigniarange.com Last Modified: 10/10/2019 There are 3 bathroom electrical zones that have been distinguished in the IEE wiring guidelines and these are: Zone 0 is the area inside a bath, basin or shower. It's characterised as 'any area within a bathroom that can hold water'. Any fitting or electrical appliance utilised inside zone 0 must be a maximum of 12 volts (SELV) and completely secured against both partial and total submersion in water (minimum of IPX7) Zone 1 is the region straight above zone 0 to the height of 2.25m from the base of the bath or shower.
  • Page 34: Weee Compliance Statement

    (EEE) have to fulfil certain obligations. Under the WEEE directive Insignia is considered the producer of certain products we supply and in line with the demands of the legislation we are pleased to offer the op- portunity to return these products to us for treatment and recycling.
  • Page 35 All images are subject to copyright. Images may not be used in any way shape or form with out written permission from Maclean International Ltd. Images are NOT permitted to be saved, printed or uploaded. Violation of copyright laws are punishable by law. Insignia™ is a registered trademark of Maclean International Ltd...