Mitsubishi Heavy Industries FDUA160AVSAVH Service Manual page 45

Duct connected-high static pressure type
Table of Contents

Advertisement

b) Power PCB
• Model FDUA160VH
This PCB is a general PCB. Replace the PCB according to this instruction.
i) Replace the PCB
① Unscrew terminal of the wiring(yellow/green) connected to terminal block (CNWO) from the box.
This PCB is a general PCB. Replace the PCB according to this instruction.
② Replace the PCB only after all the wirings connected to the connector are removed.
③ Fix the board such that it will not pinch any of the wires.
i)Replace the PCB
④ Reconnect the wirings to the PCB. Wiring connector color should match with the color of connector of the PCB.
Unscrew terminal(Arrow A) of the "E2" wiring(yellow/green) that is connected to PCB.
⑤ Screw back the terminal of wiring, that was removed in ①.
Replace the PCB only after all the wirings connected to the connector are removed.
Fix the board such that it will not p inch any of the wires.
ii) Power PCB
Reconnect the wirings to the PCB. Wiring connector color should match with the color of connector of the PCB.
Screw back the terminal(Arrow A) of the "E2" wiring, that was removed in 1.
Parts mounting are different by the kind of
• Models FDUM50VH
ii)Power PCB
Parts mounting are different by the kind of PCB.
CNW3(White)
Terminal block
CNW1(White)
Control PCB
CNW1(White)
Control PCB
CNW3(White)
Terminal block
PCB
.
CNM1(White)
Part number
CNM2(Black)
Fan motor2
44
-
-
Fan motor
CNM1(White)
Fan motor1
'21 • PAC-SM-398
PSC012D021
B
CNW0(White)
Terminal block
CNWR(White)
Reactor
CNW0(White)
Terminal block
Part number