5: Technical Specifications; Air Supply; Electrical Specifications - Panduit PDM Operation Manual

Automatic cable tie installation system
Table of Contents

Advertisement

© Panduit Corp. 2013

5: TECHNICAL SPECIFICATIONS

5A: Air Supply
Recommended regulated air pressure to dispenser
(pressures other than recommended may result in
unsatisfactory operation):
Air consumption at 25 cycles per minute:
Line pressure to regulator:
Filter/regulator requirements:
Lubrication for air supply:
Recommended filter/regulator unit (supplied by user)
3/8" NPT ports:
Recommended main air supply hose from
filter/regulator to dispenser (supplied by user):
Recommended female quick disconnect for main air
supply (supplied by user): The dispenser is furnished
with a male quick connect plug that will fit the listed
female interchangeable couplers or their equivalents.
5B: Electrical Specifications
ITEM
Line Voltage (PDM Dispenser)
Power
Phase
Line Fuse(s)
Power to Tool
This unit includes EMI/RFI filters, however it is possible that infrequent electrical phenomena may cause tool function to be
temporarily interrupted. This interruption can be corrected by turning the tool "off" (removing the cable tie if necessary), and then
back "on" again.
OPERATION MANUAL
ITEM
MODEL
All
All
All
All
All
Page: 8 of 39
DESCRIPTION
Regulator settings: 65 PSIG (4,5 bar) with a max. 10
PSI (0,7 bar) drop.
DO NOT EXCEED 85 PSIG (5,8 bar).
7 cfm @ 65 PSIG (3,3 l/sec @ 4,5 bar)
Minimum 70 PSIG (4,8 bar),
Maximum 125 PSIG (8,5 bar)
40 micron maximum element rating, 5 PSI (0,3 bar)
maximum pressure drop @ 70 PSIG (4,8 bar) inlet
pressure and 12 cfm (5,7 l/sec) flow minimum.
Air line lubricators are NOT to be used.
Recommended source:
Panduit Part Number PL283N1 (See Page 3).
Recommended source:
Panduit Part Number PDH10-37 (See Page 3).
Recommended source:
1.
Truflate type 2 & 4, 1/4" couplers
2.
Hansen series 1000 & 3000 couplers
3.
Foster series 3 & FM3, 1/4" couplers
4.
Snap-tite series 31 couplers
5.
Daisen Couplings 22-SH (Japan)
6.
Obac Corporation, Series 25 (Germany)
DESCRIPTION
100 / 115 / 230 V (50/60 Hz)
300 W
Single Phase
F 4 A, 250 V (2) - Panduit # CA21138A01
Logic -- 5 V
, 50 mA
Motor -- 24 V
, 1A (mean)
PAT1M, PAT1.5M, PDM
ENGLISH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pat1.5mPat1m

Table of Contents