Level 2 - SETUP MENU ACCESS
Resets load and/or counter
Reset Ld
Reset Ct
Level 3 - Total Counts Menu
Shows total counts
Counters
Escape
LEVEL 3A - Dispenser and Tool Counts
PDM
# XXXXXX
PAT1M
# XXXXXX
If "Tie in Tool" feature is turned "ON" and you want to turn it "OFF", just repeat this process.
ERROR 6 - Tie in Tool
Tie in Tool
POSSIBLE CAUSE: This occurs if the cable tie reaches the tool, but is prevented from completing the cycle.
This may be due to a large air pressure drop, too large of a bundle; improper feeder hose connections, an
obstruction blocking the cable tie path; a severe bend or twist in the feeder hose, or the tool jaws are opened
during the cycle.
CORRECTIVE ACTION: Remove the cable tie and any obstruction from the jaw area. Resume operation.
PREVENTION: To prevent this problem from recurring, verify that the feeder hose connections are secure and
that there are no severe bends or twists in the feeder hose. Verify that the maximum bundle diameter does not
exceed .82" (21mm) for the PAT1M Tool; and 1.31" (33mm) for the PAT1.5M Tool. Also, verify that the air
pressure is between 65 and 85 PSIG (4,5 and 5,8 bar), with a maximum 10 PSI (0,7 bar) drop.
NOTE: PDM with software revision earlier than Revision 0.8 (visible on display for 5 seconds during power
"ON"), require the following operator corrective action: (same possible cause and prevention apply).
Tie in Tool
Help
CORRECTIVE ACTION: Press the BUZZER button to turn the buzzer signal "OFF". Remove the cable tie and
any obstruction from the jaw area and verify the head is clear. Press the CONTINUE button to resume
operation.
OPERATION MANUAL
XXXXXXX
Exit
XXXXXXX
MENU
Exit
Rev X.X
Cycles:
Cycles:
MENU
Buzzer
Buzzer
Continue
Page: 39 of 39
PAT1M, PAT1.5M, PDM
ENGLISH
1. Press BUTTON 3, two times
2. Press BUTTON 1, one time
3. Brings up Level 3
(Note: Count buttons from left to right)
Press the COUNTERS button
1. Press BUTTON 3, two times
XXXXXXX
2. Press BUTTON 2, two times
XXXXXXX
3. Press BUTTON 3, one time
4. Then press BUTTON 4 to exit
5. Then press ESCAPE button
from Level 3 menu (above)
PDM Software, Revision 0.8 or
higher
PDM Software, Revision 0.7 or lower