Panduit PDM Operation Manual page 38

Automatic cable tie installation system
Table of Contents

Advertisement

© Panduit Corp. 2013
MESSAGE
Tie in hose - press air
Cable tie is caught or remains in
burst
feeder hose upon actuation due to
a severe bend or twist in the feeder
hose, low air pressure, or an
interrupted cycle.
Blocked hose - failed
Tool was actuated while a cable tie
back pressure test
(or ties) was still in the feeder
hose.
Blocked or dirty exit
Exit (optical) sensor in the
sensor
dispenser is obstructed due to a
cable tie or excess debris (dirt,
grime).
Blocked or dirty tool
Tool (optical) sensor is obstructed
sensor
due to a cable tie or excess debris
(dirt, grime).
Tie stuck in exit
The dispenser exit sensor in is
sensor
blocked so that a cable tie cannot
exit the dispenser. It may be
blocked by another cable tie that
was not removed from an earlier
cycle.
Tie stuck in tool
Cable tie has stopped in the tool
sensor
sensor area of tool.
Detent sensor
Tip collector full. Detent sensor
blocked or dirty
blocked by detent cam, foreign
object, or detent sensor lens is
dirty.
Internal regulator
Internal regulator was adjusted
incorrectly set, low
incor-rectly, or the piston is not fully
shifting.
Internal regulator
Internal regulator was adjusted
incorrectly set, high
incorrectly.
*If the cable tie does not come out freely, turn the dispenser "off" and then "on" again, to reset the rotary receiver's position.
OPERATION MANUAL
POSSIBLE CAUSE
Page: 33 of 39
PAT1M, PAT1.5M, PDM
ENGLISH
CORRECTIVE ACTION
1. Press "Buzzer" button to turn buzzer "off".
2. Straighten feeder hose to eliminate any bends or twists,
and point tool away from yourself and others.
3. Press "Air burst" button to dislodge and advance cable tie
to jaw area of tool. Press several times, if necessary.
When cable tie is advanced to jaw area, "Tie in tool"
message will appear and buzzer will sound.
4. Press "Buzzer" button to turn buzzer "off".
5. Remove cable tie from jaw area and press the "Continue"
button.
6. Press "Load" button to load one (1) cable tie and resume
operation.
7. If the cable tie does not advance to the tool jaw area after
depressing the "Air Burst" button several times, replace
the feeder hose with another and notify your maintenance
department.
Follow corrective action for "Tie in hose - press air burst" error
above.
1. Press "Buzzer" button to turn buzzer "off".
2. Disconnect feeder hose from dispenser. Look for cable tie
in dispenser connector block and remove cable tie, if
present.* Reconnect feeder hose, and resume operation.
If cable tie is not found, reconnect feeder hose. Follow the
same Corrective Action for "Tie in hose - press air burst"
error to remove the cable tie from the system.
3. If the same error is repeated, clean the dispenser exit
sensor lens (Refer to the Cleaning the Dispenser Exit
Sensor Lens section on Page 29).
1. Press "Buzzer" button to turn buzzer "off".
2. Disconnect feeder hose from tool. Look for cable tie in tool
or tool end of hose and remove cable tie, if present.
Reconnect feeder hose, and resume operation. If cable tie
is not found, reconnect feeder hose. Follow the same
Corrective Action for "Tie in hose - press air burst" error to
remove the cable tie from the system.
3. If the same error is repeated, the tool sensor lens may
require cleaning. Contact your maintenance department to
have the tool sensor lens cleaned.
1. Press "Buzzer" button to turn buzzer "off".
2. Disconnect air hose and feeder hose from dispenser. Look
for cable tie in dispenser connector block and remove cable
tie, if present.* Reconnect air hose and feeder hose, and
resume operation. If cable tie is not found, reconnect air
hose and feeder hose. Follow the same Corrective Action
for "Tie in hose -press air burst" error to remove the cable
tie from the system.
3. If the same error is repeated, clean the dispenser exit
sensor lens (Refer to the Cleaning the Dispenser Exit
Sensor Lens section on Page 29).
1. Press "Buzzer" button to turn buzzer "off".
2. Follow corrective action for "Blocked or dirty tool sensor"
error above.
1. Press "Buzzer" button to turn buzzer "off".
2. Remove cable tie from jaw area of tool.
3. Press the "Continue" button and resume operation.
4. If message reappears, notify maintenance department.
1. Press "Buzzer" button to turn buzzer 'off" and resume
operation.
2. If message remains, system will not operate. Write down
message and notify maintenance department.