5-3
Troubleshooting Guide
5-3-1 Remedies for Problems
5
5-8
Problem
Failure notification is not given.
The date or time of the RAS log
does not match the date or time
of the OS.
Insufficient memory
Possible cause
A signal selector or other device
is being used with the PS/2
keyboard or PS/2 mouse.
There is a Windows system
error.
Failure notification is disabled.
The DIP switch is set to disable
the Action on Errors Function.
The date or time in the OS was
changed.
The memory capacity is
insufficient.
Remedy
Make the connections directly
without using a signal selector.
Contact an OMRON sales
representative if the Windows
XP Embedded OS does not
operate properly.
Enable failure notification. Refer
to 4-4-2 Setting the Failure
Notification Function.
Set the DIP switch to disable the
Action on Errors Function and
restart the device. Refer to 3-2
Installing a PCI Board and
Setting the DIP Switch.
Set the time for RAS before
setting the time for the RAS
Utility. Refer to 4-4-4 Log Filter
(Filter and Find).
Close unnecessary applications.
If memory is still insufficient even
after unnecessary applications
have been closed, setup virtual
memory. Refer to Appendix 6
Using Virtual Memory.