Head part of ER-X series
Thank you very much for purchasing Panasonic products. Read this Instruction Man-
ual carefully and thoroughly for the correct and optimum use of this product. Kindly
keep this manual in a convenient place for quick reference.
● This product produces high voltages.
● Do not use this product in places where there may be a danger of flam-
mable or combustible items being present.
● To prevent electric shock and to conduct proper discharge, be sure to
ground a frame ground (F.G.) terminal of a controller.
● Do not place hands near the discharge needle. Doing so may cause elec-
tric shock.
● Since the tip of the discharge needle is sharp, take sufficient care in han-
dling the discharge needle, or injuries may result.
● The high-voltage cable between the head and the high-voltage unit must
be fixed and the minimum bend radius is R30 mm or more.
In case of using at
the bend radius
part may cause fire and break down, etc. of the high-voltage cable.
● Clean the discharge needle regularly (about once a week). Otherwise, op-
timum charge removal performance may not be achieved, and accidents
or operating problems may occur.
● If this product is used in a confined space, ozone emitted from this prod-
uct may be detrimental. Be sure to provide ventilation.
● Do not direct ionized air toward the face. Ozone may cause irritation to
places such as the nose and throat.
1
CAUTIONS
● This product has been developed / produced for industrial use only.
● Use this product with controller of ER-X series (optional) and head connec-
tion cable (optional).
● Do not use this product for purposes other than electric charge removal.
● Do not use this product in environments which are outside the specification
range, otherwise operating problems or damage may occur. In addition, the
operating life of the product may become significantly reduced.
● This product is a precision device. Do not apply a shock to it by dropping,
for example. Accidents or operating problems may occur.
● Never disassemble, repair or modify this product. Accidents or operating
problems may occur.
● Do not throw this product in fire. It may explode or toxic fumes may be gen-
erated.
● Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
● When connecting/removing the head or performing wiring or inspection
work, be sure to turn off the power first. Not doing so may result in acci-
dents, electric shock or operating problems.
● When using as a CSA and UL compliant product, use a CLASS 2 CSA/
UL certified power supply, or a CSA/UL certified power supply that has
been evaluated as a Limited Power Source as specified in CAN/CSA-
C22.2NO.60950-1/UL60950-1.
● After connecting the cables, check that the connections are correct before
turning on the power. If the cables are connected incorrectly, operating
problems or accidents may occur.
● Do not use any cables which have any damage (such as splitting or crack-
ing), otherwise operating problems or accidents may occur.
● Avoid using the product in places where there are high levels of steam or dust
in the air or where it might be directly exposed to water, oil or welding spatter.
● Do not touch the discharge needle with hard objects such as tools. If the dis-
charge needle becomes broken, it will not provide sufficient charge removal
performance, and moreover operating problems or accidents may occur.
● Avoid use at an elevation higher than 2000m, and outdoor use.
● When cleaning or replacing the discharge needle, takecare not to damage
the tip of the discharge needle.
● During installation, fasten the product securely. If it is not securely fastened
or it is subjected to continuous vibration or shock, accidents or operating
problems may result.
● When disposing of this product, treat it appropriately as industrial waste.
● Use the correct combination of head, dischargeneedle unit and controller.
● ER-X001and ER-X008 should be used with new types of controllers. If
connected to a previous type of contromtoller, after the power is on, the error
indicator lights up or blinks. New and old controllers can be distinguished
by their discharge frequency setting switches. New types show the numbers
20 and 50 in white-on-black.
Old type
2
CE MARKED PRODUCT
● Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
INSTRUCTION MANUAL
ER-X□
CMJECK-ERXH No.0053-84V
WARNING
R30
mm
or less
and using at moving
New type
3
CSA/UL compliant product
● This product complies with CSA and UL standards, and has been certified
by TUV SUD.
4
RoHS DIRECTIVE
● This equipment complies with RoHS (EU).
5
DIMENSIONS (Unit: mm)
<ER-X001>
● Head part
12
16
14
● High-voltage unit
High-voltage cable (Air tube is inside) ø10.5
2-6.5 mounting holes
6
38
ø6 air tube fitting (360°turn)
10.5
(18)
12 core connector
<Except ER-X001>
● Head part
28.5
9.4
40
40
Model No.
2-6.5
A
B
C
D
6.2
(E)
● High-voltage unit
6
17
2-6.5 Mounting holes
2-4.5 Mounting holes
38
10.5
(18)
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
PRINTED IN JAPAN
M3 screw
6.2
70
44
24
Discharge
needle unit
Ion air outlet
6
8
Bracket (removable)
(17)
(20.5)
210
210
165
222
B
28.5
A
(E)
D
C
ER-X008
ER-X016
ER-X032
ER-X048
40
120
280
440
106
194
354
514
138
226
386
546
150
238
398
558
163
251
411
571
180
160
High-voltage cable ø6.9
31
170
162
192
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
9.4
22
18
ER-X064
600
674
706
718
731
Need help?
Do you have a question about the ER-X Series and is the answer not in the manual?
Questions and answers