Download Print this page

Panasonic ER-X Series Instruction Manual page 3

Area ionizer
Hide thumbs Also See for ER-X Series:

Advertisement

4
WIRING
Power connector Pin arrangement
Terminal
No.
1
2
1
2
3
4
5
3
6
7
8
9
10
4
5
(Front view)
6
Housing: 5569-10A
7
>0DQXIDFWXUHG E\ 0ROH[ ,QF@
8
9
10
Note: Wire colors are colors of power supply cable of option.
When connecting the output to negative common
(Brown)+V
COM(+)
(Violet) COM(OUT)
(Orange) Alarm output
(Black) Error output
(Pink) Discharge control input
(White) COM(IN)
8
8
(Blue)0V
COM(-)
(Green/Yellow)F.G.
When connecting the output to positive common
(Brown)+V
COM(+)
8
(White) COM(IN)
(Pink) Discharge control input
(Orange) Alarm output
(Black) Error output
(Violet) COM(OUT)
(Blue)0V
COM(-)
(Green/Yellow)F.G.
*1
Non-voltage contact or
PNP transistor/open collector
or
Contact "closed" or transistor ON: Discharge halt
Contact "open" or transistor OFF: Starting discharge
Notes 1) In order to prevent electric shock and perform proper discharge , be sure to ground the F.G. terminal.
In addition, the head of ER-X001 and the F.G. terminal of a controller are common.
2) To stop discharge, turn ON the discharge control input for 20 ms or longer. To start discharge, turn OFF (open)
the discharge control input. Discharge will start in 20 ms.
5
PIPING
Air supplied to this product will reduce contamination of the discharge needle and
improve the charge removal speed.
7KH RXWHU GLDPHWHU RI WKH DLU WXEH WR ¿W WR WKH DLU LQOHW SRUWLRQ RI WKLV SURGXFW VKRXOG
be ø6 mm.
Make sure that clean air (air containing no water, no oil and no dust) should be
supplied.
Since the pressure will drop when the air piping from the main pressure supply
LV H[WHQGHG RU SQHXPDWLF FRPSRQHQWV HJ QHHGOH YDOYH VSHHG FRQWUROOHU PLQL
¿OWHU DUH DGGHG NHHS DQ H\H RQ WKH SUHVVXUH VXSSO\ WR WKH LRQL]HU PDNLQJ VXUH
it is not in short supply. For the pneumatic components, select those that can
DFFRPPRGDWH WKH DLU VXSSO\ ÀRZ UDWH
Except ER-X001
Piping in the head
ø6 mm tube
ER-X001
Piping in the High-voltage unit
6mm air tube
Note: After inserting the tube into the joint of this product, always make sure that the tube is all the way in and securely
inserted.
,QVXI¿FLHQW WXEH LQVHUWLRQ ZLOO FDXVH DLU OHDNDJH
Terminal name
Color code
0V
Blue
COM(-)
Discharge control input
Pink
COM(OUT)
Violet
F.G. terminal
Green/Yellow
24V
Brown
COM(+)
COM(IN)
White
Alarm output
Orange
Error output
Black
Load
24V DC
10%
1
Load
(Be sure to ground.)
2
24V DC
Load
10%
Load
(Be sure to ground.)
*2
Non-voltage contact or
NPN transistor/open collector
or
Contact "closed" or transistor ON: Discharge halt
Contact "open" or transistor OFF: Starting discharge
Head section
Air inlet
(11.4mm)
High-voltage unit
Air inlet
(11.6mm)
6
SETTING
The amount of ion generation is set to enable appropriate charge removal.
$IWHU PRXQWLQJ WKH KHDG IROORZ WKH SURFHGXUHV EHORZ WR FRQ¿JXUH WKH VHWWLQJ
:KHQ DLU LV XVHG FRQ¿JXUH WKH VHWWLQJ ZKLOH VXSSO\LQJ DLU
Start the setting after 30 minuets of the discharge starting.
How to set the amount of ion generation
1. Turn the discharge control switch ON and the discharge
control input "open" to start discharge.
Make sure that the discharge indicator (green) lights up.
2. Depending on the installation distance, set the frequency using the discharge
frequency setting switch.
Guideline when air is not supplied
Discharge frequency
Installation distance
setting switch
For head 1
For head 2
30 50mm
50 200mm
200 500mm
Discharge would be stopped at
"Test A"
and "Test E" of Head 2.
500 1,000mm
When air is supplied,
6HW WKH IUHTXHQF\ KLJKHU WKDQ ZKHQ DLU LV QRW VXSSOLHG 7U\  +] IDFWRU\ GHIDXOW
setting) first to see if it removes static electricity. Since using air, discharge
distance from the object can be longer.
If the amount of static build up on the charge removing object is large,
Set the frequency lower or make the installation distance shorter.
In case the voltage resistance of the object is low,
Set the frequency higher or make the installation distance longer.
Note: Depending on the head, different frequencies are accepted. If it is set to a wrong frequency, the discharge stops
and the discharge indicator blinks. For accepted frequencies, refer to
3. After mounting the head, adjust ion balance using the ion balance setting switch.
Ion balance setting switch
For head 1
For head 2
Turn to "-" to shift ion balance to the "-" side.
Turn to "+" to shift ion balance to the "+" side.
Note: Generally, ion reaching the charge removing object is affected by installation environment (nearby metals,
temperature, humidity, etc.). Although this product has been adjusted for ion balance at the factory, the preadjusted
ion balance may differ, depending on the customer's installation environment. For more appropriate static removal,
please adjust ion balance according to your installation environment.
4. Press the SET UP button to lock in the setting. After the
setting is completed, level meter indicators change from
blinking to lighting up.
Notes: 1) Conduct the maintenance before setting.
2) Before the setting up, be sure that the check indicator is turned OFF. In case the check the indicator lights up
or blinks, the set up is not started. For detail , reffere to
 7KLV SURGXFW ZRUNV DW IDFWRU\ VHWWLQJ EHIRUH ¿QLVKLQJ VHWXS OHYHO PHWHU LQGLFDWRU EOLQNV $QG LRQ EDODQFH
control function works at OFF in despite of setting of ion balance control switch. After press down the set up
EXWWRQ DQG ¿QLVKLQJ KH VHWWLQJ OHYHO PHWHU LQGLFDWRU OLJKWV XS  VWDUWV LRQ EDODQFH FRQWURO DQG &KHFN GHWHFWLRQ
detecting function of ion generation depression
4) It takes 30 seconds to 1 minute to complete a setup procedure. Do not change the ambient environment at the
time. In case ambient environment is changed, the set up is not conducted and level meter indicator may blink.
5) In case the discharge frequency setting switch or the ion balance control switch is changed or installed envi-
ronment is changed, conduct the setup again.
6) The set up is conducted to two heads. Do not wire head that you do not use.
7) Setting the ion balance setting switch shown right, level meter indicators blink. And pushing down the SET
UP button for 3 seconds in this setting, the setting will be the factory setting.
,QLWLDOL]LQJ PRGH IRU KHDG 
Various setting switch
Various setting
Name
switch
Switches between ion generation levels to output an alarm.
Check level
ON: Lights up the CHECK indicator and outputs an alarm, when ion
changeover switch
generation is reduced to a level that affects static removal.
OFF: Set this if you wish to be alerted soon after ion generation is reduced.
Switches between automatic ion balance control function settings.
ON: Enables automatic ion balance control function.
Senses the amount of ion generation and automatically controls it
Ion balance
to match the setting of the ion balance setting switch.
control switch
OFF: Disables automatic ion balance control function.
Ion continues to generate at the discharge ratio setting of the ion
balance setting switch.
Switches between indications of the level meter indicator (green).
ON: Indicates the static buildup state of immediate
head. It shifts to the "+" or "-" side depending on the
amount of buildup.
([DPSOH :KHQ WKH FKDUJH UHPRYLQJ REMHFW LV
positively charged.
Indicator change-
over switch
OFF: Indicates the amount of ion the head generates. Plus
ion generated is indicated on the "+" side and minus
ion on the "-" side.
([DPSOH :KHQ D VXIILFLHQW DPRXQW RI SOXV DQG
minus ions are generated.
Sets ion generation timing for two heads. If the two heads have different
discharge frequency, this setting will be invalid, and ion will be generated
at the frequency timing of each head.
2 heads control
ON: When head 1 is generating plus ion, head 2 also generates plus ion.
switch
(synchronous mode)
OFF: When head 1 is generating plus ion, head 2 generates minus ion.
(inversion mode)
Not used.
Notes: 1) All factory default settings are ON.
2) Checking function (detecting function of ion generation depression) is based on amount of ion generation
which was set in the set up.
Discharge control switch
Discharge
frequency setting
Frequency
switch
100
+]
70
+]
50
+]
30
+]
20
+]
10
+]
5
+]
1
+]
"12
SPECIFICATIONS"
SET UP button
9
TROUBLE SHOOTING."
amount based on your enviroment.
,QLWLDOL]LQJ PRGH IRU KHDG 
Function

Advertisement

loading