FOR SAFETY USE

This product produces high voltages.
Do not use this product in places where there may be a danger of flammable or
combustible items being present.
To prevent electric shock and to conduct proper discharge, be sure to ground a frame
ground (F.G.) terminal of a controller.
Do not place hands near the discharge needle. Doing so may cause electric shock.
Since the tip of the discharge needle is sharp, take sufficient care in handling the
discharge needle, or injuries may result.
7KH KLJKYROWDJH FDEOH EHWZHHQ WKH KHDG DQG WKH KLJKYROWDJH XQLW PXVW EH ¿[HG DQG
the minimum bend radius is R30 mm or more.
In case of using at the bend radius R30 mm or less and using at moving part may
FDXVH ¿UH DQG EUHDN GRZQ HWF RI WKH KLJKYROWDJH FDEOH
Clean the discharge needle regularly (about once a week). Otherwise, optimum charge
removal performance may not be achieved, and accidents or operating problems may
occur.
,I WKLV SURGXFW LV XVHG LQ D FRQ¿QHG VSDFH R]RQH HPLWWHG IURP WKLV SURGXFW PD\ EH
detrimental. Be sure to provide ventilation.
'R QRW GLUHFW LRQL]HG DLU WRZDUG WKH IDFH 2]RQH PD\ FDXVH LUULWDWLRQ WR SODFHV VXFK DV
the nose and throat.
This product has been developed / produced for industrial use only.
Do not use this product for purposes other than electric charge removal.
Do not use this product in environments which are outside the specification range,
otherwise operating problems or damage may occur. In addition, the operating life of the
SURGXFW PD\ EHFRPH VLJQL¿FDQWO\ UHGXFHG
7KLV SURGXFW LV D SUHFLVLRQ GHYLFH 'R QRW DSSO\ D VKRFN WR LW E\ GURSSLQJ IRU H[DPSOH
Accidents or operating problems may occur.
Never disassemble, repair or modify this product. Accidents or operating problems may
occur.
'R QRW WKURZ WKLV SURGXFW LQ ¿UH ,W PD\ H[SORGH RU WR[LF IXPHV PD\ EH JHQHUDWHG
Do not run the wires together with high-voltage lines or power lines or put them in the
same raceway.
This can cause malfunction due to induction.
When connecting/removing the head or performing wiring or inspection work, be
VXUH WR WXUQ RII WKH SRZHU ¿UVW 1RW GRLQJ VR PD\ UHVXOW LQ DFFLGHQWV HOHFWULF VKRFN RU
operating problems.
After connecting the cables, check that the connections are correct before turning on the
power. If the cables are connected incorrectly, operating problems or accidents may occur.
Verify that the supply voltage variation is within the rating.
In case using switching regulator, be sure to connect F.G. terminal.
Do not use any cables which have any damage (such as splitting or cracking), otherwise
operating problems or accidents may occur.
Avoid using the product in places where there are high levels of steam or dust in the air
RU ZKHUH LW PLJKW EH GLUHFWO\ H[SRVHG WR ZDWHU RLO RU ZHOGLQJ VSDWWHU
Do not touch the discharge needle with hard objects such as tools. If the discharge
QHHGOH EHFRPHV EURNHQ LW ZLOO QRW SURYLGH VXI¿FLHQW FKDUJH UHPRYDO SHUIRUPDQFH DQG
moreover operating problems or accidents may occur.
During installation, fasten the product securely. If it is not securely fastened or it is
subjected to continuous vibration or shock, accidents or operating problems may result.
2
Power cable that are 0.15mm
or more and 30m or less in total length for wiring.
Also, keep the wiring as short as possible in order to prevent noise.
When disposing of this product, treat it appropriately as industrial waste.
$IWHU VWDUWLQJ GLVFKDUJH LW WDNHV DSSUR[LPDWHO\  PLQXWHV IRU FKDUJH UHPRYDO
SHUIRUPDQFH WR VWDELOL]H 7KHUHIRUH ZDLW  PLQXWHV EHIRUH DGMXVWLQJ LRQ EDODQFH
Use the correct combination of head, discharge needle unit and controller.
2

PART DESCRIPTION

Discharge needle unit
ER-XANT or ER-XANS
Air inlet
Head
mounting
Head
bracket
(5;
Discharge
needle
Head connection cable
ER-XCCJ2H, ER-XCCJ5H or ER-XCCJ10H
Controller
ER-XC02
Power cable (optional)
ER-XCC2 or ER-XCC5
Note: The minimum bend radius of the high-voltage cable is R30 mm.
INSTRUCTION MANUAL
CME-ERX No.0046-89V
WARNING
WARNING
CAUTION
High-voltage cable (Note)
High-voltage unit
Discharge needle unit
Head
ER-XANT1
ER-X001
Bracket
High-voltage cable (Note)
High-voltage unit
Air inlet
<Controller>
Level meter indicator (green)
Indicates static buildup around the
head or the amount of ion generated
from the head.
Discharge control switch
ON: Discharge allowed
OFF: Discharge halt
SET UP button
Stores the settings for the
amount of ion and the check
threshold in memory.
Note: An abbreviation of DISCHARGE.
3

INSTALLATION

<Head installation>
Using 2 M4 screws or 1 M6 screw, mount the head
onto the equipment housing. In case using this prod-
uct in where there is vibration, use spring washers
etc. as a countermeasure.
Loosen the angle adjustment screw, adjust the head
angle, and then fasten the head with the tightening
WRUTXH RI  1ÂP RU OHVV
The position of the head mounting bracket of the ER-X001
should be at least 20 mm from the end of the head. The
WLJKWHQLQJ WRUTXH RI WKH VFUHZ IRU KHDG ¿[DWLRQ VKRXOG EH
 1‡P RU OHVV
After mounting the head, set the controller according
to the procedures in "
6
SETTING" in order to
appropriately remove static electricity.
Notes: 1) Be sure to ground the equipment housing onto which the head is mounted.
2) The distance between the head and the charge removing object should be 30 mm or more.If the static
buildup of the charge removing object is 30 kV or more, set the distance to 50 mm or more.
3) If there is metal near the head or between the head and the charge removing object, ion is absorbed,
hindering appropriate static removal. Install the head based on the above.
 ,Q FDVH XVLQJ WKH VLGH PRXQWLQJ WKH GLVFKDUJH IUHTXHQF\ VKRXOG EH +] RU PRUH
Back-side mounting
(All frequencies)
50mm or more
Surrounding
metal
7KH GLVFKDUJH PX]]OH
PXVW H[FHHG WKLV OLQH
(surrounding metal.)
5) When installing two or more heads in face to face or parallel using different frequency, keep the distance be-
tween the heads 400mm or more.
When installing the heads face to face, install heads in distance that the heads can parform the charge
removal of a side of the object individualy.
Face-to-face installation
100mm
100mm
or more
or more
<High-voltage unit installation>
Use 2 M4 screws or 2 M6 screws to fasten the
head.
The tightening torques for fastening, are as follows.
When using M4 screws: 1.2N·m
When using M6 screws: 2.5N·m
Notes: 1) Do not place any objects on top of the high-voltage unit.
2) When using multiple heads, keep the distance of at least 10 mm
between the high-voltage units.
3) When fastening the high-voltage unit using M6 screws, fasten
before connecting the head connection cable.
 3OHDVH ¿[ WKH KLJKYROWDJH XQLW RI ER-X001 with M6 screw.
<Controller installation>
Mount the controller on a 35 mm wide DIN rail or using M4 screws. For mounting
dimensions, refer to "
15
DIMENSIONS"
When mounting on a DIN rail
Lock release
lever
2
1
35 mm wide DIN rail
Pull the lock release lever to remove this
product from the DIN rail.
Discharge indicator (green) (Note)
Lights up during discharge , blink-
ing during discharge stopped.
CHECK indicator (orange)
Lights up when dirt, wear, etc. of
the discharge needle is detected.
ERROR indicator (red)
Lights up when abnormal
discharge is detected.
Discharge frequency setting switch
Switches between discharge
frequency settings.
Ion balance setting switch
Sets ion balance.
Various setting switch
Refer to "
6
SETTING."
Angle adjustment
screw
M4 screw
Angle adjustment
screw
M6 screw
Screw for
KHDG ¿[DWLRQ
Side mounting
Mouting ER-X001
+] RU PRUH
50mm or more
Surrounding
metal
20mm
or more
Parallel installation
50mm or more
M6 screw
M4 screw
10mm or
more
When mounting using M4 screws
M4 screw
The tightening torque should be 1.2 N·m or
less.
M4 screw
20mm
or more
50mm
or more

Advertisement

loading

This manual is also suitable for:

Er-x001Er-x008Er-x016Er-x032Er-x048Er-x064