Download Print this page
Panasonic ER-F Series Instruction Manual

Panasonic ER-F Series Instruction Manual

Static remover fan-type ionizer

Advertisement

Quick Links

Static Remover Fan-type Ionizer
ER-F12 / ER-F12S
Thank you very much for using Panasonic products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
WARNING
Never use this product with a device for personnel protection.
In case of using devices for personnel protection, use products which meet laws
or standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable
in each region or country.
Do not use this product in places where there may be a danger of � �ammable or
combustible items being present.
Clean the discharge needle regularly (about once every two weeks), otherwise
optimum charge removal performance may not be obtained and � �re or operating
problems may occur.
If this product is used in an airtight room, ozone emitted from this product may be
detrimental. Therefore, in order for this product to be used in an airtight room, be
sure to keep the room ventilated.
Do not direct ionized air toward the face. Ozone may cause irritation to places
such as the nose and throat.
Since the tip of the discharge needle is sharp, take ���� cient care in handling the
discharge needle, or injuries may result.
Be sure to ground the frame ground (F.G.) terminal, otherwise electric charge
removal may not be reliable.
1
OUTLINE
This product is a fan-type charge removal device which uses ion generation from
corona discharges.
The device is suitable for a variety of charge removal applications. It is equipped
with a straight louver which is ideal for long-distance charge removal, and an angle
louver which is ideal for wide-range charge removal.
The fan speed can be adjusted to one of four settings.
2
PART DESCRIPTION
Caution label (Note 2)
Louver
LEDs
Power switch
Fan speed
Bracket
select switch
Power connector
(Note 1)
Description of each LED
POWER ...........Lights up when the power is turned on.
(Power indicator)
DSC .................Lights up when discharge is occurring normally.
(Discharge indicator)
DSC ERROR ...Lights up when an abnormal discharge is detected.
(Discharge error indicator)
FAN ERROR ....Lights up when a problem with fan operation is detected.
(Fan error indicator)
Notes: 1) Fan speed select switch
At the time of shipment from the factory, the device is set to fan speed 4 (MAX). Use a
� �at-tipped screwdriver to adjust the fan speed.
Notes:
2) Caution label
Attach whichever accessory caution label is written in the appropriate language for the
region of use.
3
I/O CIRCUIT DIAGRAM
Error output
50mA max
Discharge halt input
Internal circuit
Users' circuit
D
: Power supply reverse connection protection diode
1
D
: Output protection diode
2
D
: Input protection diode
3
Z
: Surge voltage absorption Zener diode
D
T
: NPN output transistor
r
*1
Non-voltage contact or
NPN transistor/open collector
Low (0V)
: Discharge halt
or
High (Open) : Discharge (operation start)
Ramco National
INSTRUCTION MANUAL
MJE-ERF12F12S No.0031-23V
M5 screw
M5 screw
Filter cover
(From cable insertion side)
l Pin layout
30V
24V DC
Terminal no. Terminal name
DC max
±10%
F.G.
+V
0V
Error output
Discharge halt input
Recommended wire : AWG 25~12
Option (sold separately)
ER-FAPS-J: AC adapter
About wiring cable <Recommendation>
Compatible electric wire: AWG25#25 - 12
(Nominal cross-sectional area: 0.16 - 3.3 m
Work dimension of electric wire: 7 mm
(figure below)
* Do not solder-plate the end of the electric wire
to be wired to the connector. The tightened
screw may become loose and the wiring may be
disconnected.
800-280-6933 | nsales@ramcoi.com
4
MOUNTING
Be sure to turn off the power before carrying out angle adjustment for this product,
otherwise accidents or problems with operation may occur.
Remove the bracket from the main unit, and then secure it to the installation
location.
Use the holes in the base of the bracket to secure it with screws.
The vertical angle of the product can be freely changed by loosening the two M5
screws. After adjusting the angle, retighten the screws to secure the device so
that the angle will not change. The tightening torque for the M5 screws at this time
��������������������������
Attach the accessory rubber cushion to bracket as shown in the below diagram to
suit the usage.
5
OPERATION MATRIX
Indicators (
POWER
DSC
Green
Green
Normal
Discharge error
Fan error
Discharge halt input
* Once an error is detected, the error status will be maintained until the power is turned off and back
on again.
Remove the cause of the error and then turn the power back on.
If the cause of the error is not removed, the error status will continue.
* Discharge halt input is disabled when an error status is active.
6
LOUVER SELECTION
[Diagram with louver attached]
Straight louver (blue)
[Diagram of charge removal area]
1500mm
200mm
This product includes two types of louver as accessories. Select the type of louver to
use based on the charge removal area.
Straight louver
This louver provides excellent direction stability for the air. It is ideal for cases where
rapid charge removal for objects is required, or when the object is some distance away.
Angle louver
This louver is excellent at dispersing the air. It is ideal for charge removal over a wide
area.
Notes: 1) The discharge needle unit is loaded on the straight louver before shipment. To replace it
with the angle louver, refer to the discharge needle unit installation procedure in "
AND MAINTENANCE" in this manual.
Notes:
2) If no louver is attached, the device will not turn on even when the power is supplied.
7
CARE AND MAINTENANCE
Be sure to turn off the power before carrying out cleaning and maintenance.
The discharge needle has a sharp point, so be very careful when cleaning the needle.
If the device is used for a long period, dust and other foreign particles may
accumulate on the discharge needles or on the fan � �lter, and so the needles and
� �lter should be cleaned before use.
If the device is not cleaned regularly, the charge removal performance will drop and
operating problems or accidents may occur. Clean the device regularly, using the
following as a guide.
Discharge needle unit: Every 2 weeks
Fan intake � �lter: Every 2 weeks
The discharge needle is a consumable part. If the discharging performance is not
restored after the discharge needles have been cleaned, it is recommended that
you replace the discharge needle unit. It is recommended that you replace the
discharge needle unit after about 10,000 hours of operation.
Cleaning the discharge needle unit
Check that the power is turned off and that the fan has completely stopped.
Following the removal procedure of the louver, remove the louver from the main
unit.
)
Clean with the discharge needle loaded. Use a cotton swab or similar tools
2
moistened with alcohol to clean the discharge needles and the areas around them.
If the needles are particularly dirty, use a brush (such as a toothbrush) moistened
with alcohol to rub them clean, and then use a cotton swab to wipe them.
<When using a commercially-available ultrasonic cleaner for cleaning>
Following the removal procedure of the discharge needle unit, remove the
discharge needle unit from the louver, and immerse the discharge needle unit
into the cleaning tank to clean them. After that, dry the discharge needle unit well.
Following the installation procedure, install the discharge needle unit to the louver.
Following the installation procedure, install the louver to the main unit.
: Lights up,
: Off)
Error output
DSC
FAN
Discharge
(normal
ERROR
ERROR
operation
close)
Red
Red
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
Angle louver (white) (Note 1)
200mm
700mm
600mm
www.panasonicsensors.com
[Louver re
Louver
Open
Turn the l
of the arro
Louver
When
louver
turn the
* Do n
or p
[Discharge
When usin
remove th
Fan
Discha
operation
ON
OFF
OFF
ON
Hold the lou
unit counter
Discha
As sho
the claw
Turn th
Notes: 1) If
Notes:
2) W
ot
Notes:
3) �
di
Option
ER-F12
Cleaning
Install a � �l
Remove
below, a
illustratio
Clean a
wash it
Install t
* If the devic
* If the � �lter
7
CARE
* Be careful
Option
ER-F12
8
TRO
Be sur
Probl
Discharge
indicator (D
ERROR)
lights up.
Fan error in
(FAN ERRO
lights up.

Advertisement

loading

Summary of Contents for Panasonic ER-F Series

  • Page 1 Attach the accessory rubber cushion to bracket as shown in the below diagram to suit the usage. Thank you very much for using Panasonic products. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product.
  • Page 2 About our sale network, please visit our website. �� Check that there are no foreign objects inside the louver. lights up. Foreign objects product. PRINTED IN CHINA © Panasonic Industrial Devices SUNX Co., Ltd. 2012 Ramco National 800-280-6933 | nsales@ramcoi.com www.panasonicsensors.com...

This manual is also suitable for:

Er-f12Er-f12sEr-f12a