Download Print this page

olympia electronics GR-290 Manual page 4

Non maintained self testing spot light emergency limunaries with 1 white power led

Advertisement

LEDs
CHARGE
: Battery charging,
LAMP FAULT
: Operation check,
BATT. FAULT
: Autonomy test,
Note
: Blinking,
Important notice for the installed luminaires in one area !!!
The installer must connect the battery's connector first and then should power the luminaire.
The time between batteries connection must be, at least 1.5 minute.
With this variation, it is ensured that the non synchronized Automatic Autonomous Test for
two or more luminaires installed in one area, is not conducted in the same day.
Battery replacement.
It can be done only by a competent person and after the mains interruption.
1. Remove the luminaire from the suspended ceiling (figure 3).
2. Follow the step 1 of the installation instructions.
3. Disconnect the connector and remove the old battery.
4. Connect the new battery with the same type (step 2 of the installation instructions) and place it in
the position of the old one.
5. Replace the removed parts (step 1 and 4) and power the device.
125
LAMP
BATT.
CHARGE
TEST
FAULT
Lamp fault
indication LED
Battery
charge
indication
LED
CHARGE
Figure 6
Manufacturer
Model Number
Voltage Range
Nominal Power
Connections
Temperature (tc)
Page 4 from 5
Status of LEDs
Description of indication
: battery charged,
: lamp fault,
: battery fault,
: constantly on,
96
Battery
fault
indication
LED
LAMP
BATT.
TEST
FAULT
Test
button
CAUTION : Do not view directly with bare eyes.
LED MODULE CHARACTERISTICS
GR-290
Non reversible connection between main pcb and led module
60 °C max. across the board
: disconnected or unfunctional battery
: normal operation
: normal operation
: off
65
Corridor
lighting
ATTENTION!!!
During installation follow this light direction.
Open
area
lighting
GR-291
Olympia Electronics S.A
1110143
3-3.2VDC
2.2W
GR-290, GR-292
LAMP
BATT.
CHARGE
TEST
FAULT
GR-291, GR-293
LAMP
BATT.
CHARGE
TEST
FAULT
GR-292
2704143
1.1W
45 °C max. across the board
923292000_09_016
GR-293

Advertisement

loading

This manual is also suitable for:

Gr-291Gr-292Gr-293