4-1-10. SP Conn Assy 4P and LVDS Harness Dressing
Follow figures below for SP Conn Assy 4P and LVDS Harness dressing.
3
Tape, LCD attached to WHT+BLK end of wire
1
Dress SP Conn Assy 4P below LVDS harness
Attach Sheet Core, C
2
C
Attach Sheet Core, C
2
C
Tape, LCD attached to WHT+BLK end of wire
3
1
Dress SP Conn Assy 4P
below LVDS harness
4-1-11. Connector Assy 10P Dressing
Dress Connector Assy 10P using Tape, LCD (2X) as shown.
Use datum line as a guide
Use Tape, LCD (2X) to
attach Conn Assy 10P to
main bracket
Use datum line as a guide
Conn Assy 10P
CN1000
SP Conn Assy 4P
Figure (a)
19T400W Non-CISPR models
SP Conn Assy 4P
Figure (c)
Common for all
19T400 models
id
CN3001
Conn Assy 10P is
below wires
Figure 12
– 13 –
3
Tape, LCD attached to WHT+BLK end of wire
2
Screw earth clamp (X1)
1
Dress SP Conn Assy 4P below LVDS harness
Tape, LCD attached to
3
WHT+BLK end of wire
Dress SP Conn Assy 4P below LVDS harness
2
Attach Sheet Core, C
SP Conn Assy 4P
4-1-12. Dressing for 19T400W models only
1) Dress Connector Assy 7P as shown.
2) Next, dress Conn Assy 3P by inserting the wire into J-bracket's hook.
Conn Assy 3P
SP Conn Assy 4P
Insert Conn Assy 3P
2
into J -bracket's hook
LVDS Harness
KLV-19T400A,T400G,T400W
19T400A CISPR models
SP Conn Assy 4P
Figure (b)
19T400G Non-CISPR models
Caution: Dress wires
downward towards the
tweeter. Ensure capacitor
does not touch tweeter or
any coductive parts.
Figure (d)
19T400W
Conn Assy 7P
1
Dress Conn Assy 7P
below LVDS Harness