4-1-7. Lead Assy, Earth Dressing

1) Insert both Lead Assy, Earth to GT PWB and screw them on to main bracket's screw hole as shown.
2) Insert Lead Assy, Earth from GT PWB to BT PWB as shown.
3) Attach Tape, LCD to Lead Assy, Earth.
1
Lead Assy, Earth
Common for all 19T400 models

4-1-8. Wire Harness Dressing

1) Dress SP Conn Assy 4P using Tape, LCD as shown (1X).
2) Dress Lamp wire using Tape, LCD as shown (1X).
1
2
Tape, LCD
Lamp wire
SP Conn Assy 4P
CN6204
45º
Figure (a)
CN6206
1
Lead Assy, Earth
Make sure UL tube is positioned
45º
Figure (b)
19T400A models
19T400W models
Tape, LCD
Figure(a)
2
Insert Lead Assy, Earth
at the stand (to protect wire
from sharp edge).
Caution: Dress wires downward towards the tweeter.
Ensure capacitor does not touch tweeter or any
conductive parts.
– 11 –
KLV-19T400A,T400G,T400W
Commo for all
19T400 models
Use datum line as a guide
CN8002
Attach Tape,
LCD to Lead
3
Assy, Earth
Figure c
19T400G models
1
Tape, LCD
2
Tape, LCD
Lamp wire
SP Conn Assy 4P
Figure (b)
19T400G models
Figure (c)
RM-GA013