Page 4
INSTALLING THE OIL-X SYSTEM Before pressurising the filter ensure that the head and bowl are correctly fitted and that the locking detail is properly aligned as shown in the maintenance section of this manual. MODELS 050 AND 055 ONLY The lower closure plate may move when the filter is not pressurised The lower closure plate is a non serviceable item and should never be removed.
Page 5
INSTALLATION RECOMMENDATIONS It is recommended that the compressed air is treated prior to entry into the distribution system and also at critical usage points / applications. Installation of compressed air dryers to a previously wet system could result in additional dirt loading for point of use filters for a period whilst the distribution system dries out.
Page 7
START-UP PROCEDURE Before pressurising the filter ensure that the head and bowl are correctly fitted and that the locking detail is properly aligned. Slowly open the inlet valve (01) to gradually pressurise the filter and wait 1 minute (02) before slowly opening the outlet valve (03) to re-pressurise the downstream piping.
Page 9
MAINTENANCE INTERVALS To ensure optimal filter performance the OIL-X Grade AO and OIL-X Grade AA coalescing and dry particulate filter elements require changing every 12 months (8736 hours) along with the automatic float drain. Unlike coalescing and dry particulate filter elements which are changed annually to guarantee compressed air quality, the lifetime of an adsorption filter element / cartridge can be attributed to various factors and will require more frequent changes.
Page 10
SYSTEM DEPRESSURISATION Slowly close the inlet (01) and outlet (02) valves and depressurise the filter (03) using the drain. FILTER BOWL REMOVAL Unscrew the filter bowl (01 & 02) and remove the used element (03). Note: A strap wrench may be required for the removal of the 050 & 055 filter bowl. Caution 0 bar / 0 psi Safety Gloves...
Page 12
INSERTION OF REPLACEMENT OF FILTER REPLACEMENT ELEMENT HEAD O RING SEAL INTO FILTER BOWL Replace the O-ring located in the filter head with the new O-ring provided. Insert the new element into the filter bowl ensuring that the lugs are seated correctly in the grooves. Ensure to lubricate the O-ring and threads with a suitable acid free Petroleum jelly.
Page 13
SERVICE REMINDER LABEL Attach the element change date label to the filter bowl and write on the date the element is to be replaced. i.e 12 months after element change. Do not use solvents or alcohol to clean the labels as this could cause damage.
Page 14
STILL STUCK? WATCH THE HOW-TO GUIDE Watch this guide via Parker Hannifin WHAT YOU’LL FIND IN THIS VIDEO Installing the OIL-X System Start-up Procedure System De-pressurisation Filter Bowl Removal Removal of Element from Filter Bowl Automatic Drain Replacement Insertion of Replacement Element into Filter Bowl...
Page 16
MODEL CODING EXAMPLE PRODUCT SELECTION Stated flows are for operation at 7 bar g (100 psi g) with reference to 20 C, 1 bar a, 0% relative water vapour pressure. For flows at other pressures apply the correction factors shown. MODEL ELEMENT PREMIUM ENERGY...
Page 17
FILTER FLOW RATES PORT REPLACEMENT MODEL /MIN SIZE ELEMENT KIT ¼ P010 [Grade] [GRADE] PX010A ⅜ P010 [Grade] [GRADE] PX010B ½ P010 [Grade] [GRADE] PX010C ⅜ P015 [Grade] [GRADE] PX015B ½ P015 [Grade] PX015C [GRADE] ½ P020 [Grade] [GRADE] PX020C ¾...
Page 18
TECHNICAL DATA OPERATING OPERATING RECOMMENDED RECOMMENDED FILTRATION PRESSURE PRESSURE OPERATING TEMP OPERATING TEMP FILTER MODELS GRADE BAR G PSI G BAR G PSI G PX010 to 055 with float drain PX010 to 055 with float drain PX010 to 055 with manual drain PX010 to 055 with float drain PX010 to 055...
Page 19
WATER SEPARATOR WEIGHTS AND DIMENSIONS Pipe Size (port size) Bowl Removal Clearance WATER SEPARATOR WEIGHTS AND DIMENSIONS HEIGHT (H) WIDTH (W) DEPTH (D) WEIGHT PIPE MODEL SIZE ¼ 7.09 2.99 2.56 6.06 1.97 1.18 0.81 1.78 WSPX010A ⅜ 7.09 2.99 2.56 6.06 1.97...