Download Print this page
Parker Balston SR Series Installation, Operation And Maintenance Manual

Parker Balston SR Series Installation, Operation And Maintenance Manual

Steam filters

Advertisement

Quick Links

Bulletin TI-SteamSR-M
Technical Information
Balston® Series "SR"
Steam Filters
Installation, Operation, and Maintenance Manual
housing, through the Balston Grade SR Microfibre
The Grade SR Microfibre Filter Cartridge, rated at 98+% efficiency for 0.01 micron and larger particles, removes essentially all
the suspended solid particles and the remaining water droplets. The water draining from the filter cartridge and the expansion
chamber is automatically removed from the housing by the automatic condensate drain.
The Balston Grade SR Microfibre Filter Cartridge, the heart of the Model 23SR Filter, combines rugged construction with re-
markably efficient filtration of solid particles and liquid droplets. Solid particles remain trapped in the depth of the filter car-
tridge, while liquid water drips from the filter cartridge to the automatic drain. The Microfibre Filter Cartridge is constructed from
chemically inert borosilicate glass fibers and a fluorocarbon resin binder. The filter cartridge is completely free of impurities
which could extract into the steam, and is in compliance with USFDA regulations as stated.
Bulletin TI-SteamSR-M
Installation, Operation and Maintenance Manual
Balston
Series "SR" Steam Filters
®
USFDA, USDA, and 3A Compliance
Balston SR Steam Filters are in full compliance with the
requirements of the United States Food, Drug and Cosmetic
Act. These filters may be used with steam, air, and other gases
which directly contact food and food ingredients, including
milk, alcoholic and non-alcoholic liquids.
These filters also meet the regulations for Indirect Food Ad-
ditives used as Basic Components for Repeated Use Food
Contact Surfaces as specified in 21 CFR Part 177, and Current
Good Manufacturing Practices, 21 CFR Part 110.
The Balston SR Steam Filters are in full compliance with the 3A
Accepted Practices (Number 609-03) for producing steam of
culinary quality.
The Balston SR Steam Filters have also been accepted by the
USDA for use in federally inspected meat and poultry plants.
The Balston 23SR Steam Filter
What it is - How it works
The Balston 23SR Steam Filter contains a patented Microfibre
Filter Cartridge in a rugged stainless steel housing designed
specifically for steam service. Included as standard items with
the 23SR Steam Filter are a stainless steel condensate drain
and high quality bleeder valve. The unit as received is complete
and ready for installation.
As shown in the cutaway drawing, steam enters the housing
into an expansion chamber, where much of the condensate is
knocked out of the steam as a result of the abrupt change in
flow direction and velocity. The steam then flows upward in the
Filter Cartridge (outside-to-inside flow), and then downward to the exit port.
®
1
®
Parker Hannifin Corporation
Industrial Gas Filtration and
Generation Division
Haverhill, MA • 1-800-343-4048
www.balstonfilters.com

Advertisement

loading

Summary of Contents for Parker Balston SR Series

  • Page 1 The filter cartridge is completely free of impurities which could extract into the steam, and is in compliance with USFDA regulations as stated. Bulletin TI-SteamSR-M Parker Hannifin Corporation Industrial Gas Filtration and Generation Division Haverhill, MA •...
  • Page 2: Installation

    2" NPT OUTLET MANIFOLD REDUCED TO 11/2" NPT ON OUTGOING END ONLY. 2" NPT INLET MANIFOLD. REDUCED TO 11/2" ON INLET END ONLY. Typical Installation - SP3-23/75SR Steam Filter Parker Hannifin Corporation Industrial Gas Filtration and Generation Division Haverhill, MA • 1-800-343-4048 www.balstonfilters.com...
  • Page 3 To avoid personal injury and/or property damage resulting from over pressurizing the housing, Parker recommends that the customer install a pressure relieving device set at 125% of the maximum pressure rating of the housing. Model 23/75SR The single housing unit has 1"...
  • Page 4: Maintenance

    1/2" NPT Bleeder Valve Outlet 1/4" NPT Max Operating Pressure 125 psig Max Operating Temperature 350°F Flow Rate 2000, 3000 lb/hr Materials of Construction 304/304L Parker Hannifin Corporation Seals Industrial Gas Filtration and Generation Division Haverhill, MA • 1-800-343-4048 www.balstonfilters.com...
  • Page 5 Replacement Parts for 23/75SR, SP2-23/75SR, SP3-23/75SR, SP4-23/75SR, and SP6-23/75SR Order by part number (Not by item number) To ensure consistent product performance and reliability use only genuine Balston replacement parts and filter cartridges. Parker Hannifin Corporation Industrial Gas Filtration and Generation Division Haverhill, MA • 1-800-343-4048 www.balstonfilters.com...
  • Page 6 Installation, Operation and Maintenance Manual Bulletin TI-SteamSR-M Technical Information Balston Series "SR" Steam Filters ® © 2014 Parker Hannifin Corporation Printed in U.S.A. Bulletin TI-SteamSR-M 03/18 Parker Hannifin Corporation Parker Manufacturing (UK) Ltd Industrial Gas Filtration and Gas Separation & Filtration Division EMEA...

This manual is also suitable for:

Balston sp2-23/75srBalston sp3-23/75srBalston sp4-23/75srBalston sp6-23/75sr