Contents INTRODUCTION .............................. 3 DEFINITIONS AND SYMBOLS .......................... 4 GENERAL SAFETY INFORMATION ........................5 TECHNICAL INFORMATION ..........................6 Product Description ..........................6 Housing – General Layout ........................6 Spare Parts ............................9 Data Label ............................. 9 Declaration of Conformity ........................9 INSTALLATION ..............................
Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.
DEFINITIONS AND SYMBOLS Key terms are defined below, and symbols are included in Table 2 IOMI – Installation, operation and maintenance instructions Filter Housing - Vessel or container for filter cartridges or elements operating greater than atmospheric pressure (pressure envelope) Vessel - a housing designed and built to contain fluids under pressure including its direct attachments up to the coupling point connecting it to other equipment;...
– refer to Table 3 Do not perform unauthorised modifications or repairs; Parker is not liable for any modifications undertaken by end users. Do not operate outside of the pressure and temperature rating – refer to section 4.
TECHNICAL INFORMATION Ensure the process fluid is compatible with the materials of construction of the filter housing and accessories. Incompatible process fluids may impact the design specification of the filter housing resulting in injury or death. Table 4 Product Description Filter housings are pressure retaining containers that are designed to locate filter cartridges used to remove particulate from gas or liquid.
Page 7
Liquid Filter Housings (Single Round) Pos. Description Filter Housing Head Filter Housing Bowl Vent Drain Inlet Outlet Closure Seal Closure clamp Double bolt clamp (PHL and PTFE seal options) Filter Cartridge Location Lateral Port (PHL Only) Retainer spring (222 only) Support Legs (3 off) Figure 2 Liquid Filter Housings (Multi Round)
Page 8
Industrial liquid Filter Housings (Single Round) Pos. Description Filter Housing Head Filter Housing Bowl Vent Drain Inlet Outlet Closure clamp Cartridge location Tie rod (DOE only) Tie rod nut Retainer spring (222 only) Figure 4 Industrial Liquid Filter Housings (Multi Round) Pos.
A data label is etched to the main filter housing body to provide important information about the specification; For demi housings see , for single & multi housings see Figure 6Figure 6 Figure 7 Pos. Description Parker Part Code Design Pressure (Bar) Hydrostatic Test Pressure (Bar) PED Fluid Group Serial Number Demi Housings Figure 6 Pos.
INSTALLATION Please read and understand this document before installing the filter housing and accessories. Refer also to the general safety information in Table 2. Avoid subjecting the pressure equipment to external stresses. Do not use the filter housing or accessories if there are signs of damage either to the shell or sealing faces.
Connection and Assembly a) Safely isolate all supply lines that will connect to the filter housing. b) Install adequate protective equipment i.e. pressure relief valves within the pressure system to prevent an overpressure situation. All connections to the filter housing, including accessories, should be made by competent personnel. d) If the housing is damaged during installation then contact the supplier immediately and await instructions.
Filter Cartridge Installation and Replacement To remove or replace the filter cartridge in the filter housing the procedure in this section should be followed. Additionally, a risk assessment and any control measures identified should be implemented and the local environment should be declared safe, prior to opening the housing. a) All personnel handling the filter housing should be earthed.
ATEX Requirements Equipment used for operation in potentially explosive atmospheres must comply with DIRECTIVE 2014/34/EU Please read and understand this documentand any supporting equipment manuals before operating or maintaining the filter housing. Refer also to the general safety information in Table 3Error! Reference source not found..
Ensure that the filter housing and the relaxation chamber, if used, remain full of liquid during normal operation in order to prevent a flammable atmosphere. d) All Parker filter housings must be earthed; electrical continuity is achieved by the mechanical connection between conductive parts, where the parts are not coated.
Bonding Surfaces When the filter housing is assembled and installed into the process pipework, electrical continuity (bonding) is guaranteed by the mechanical connection of all the parts. Refer to Figure 8. 1 – The housing closure clamp achieves electrical continuity between the filter housing head and bowl. 2 –...
connections Bowl falls to a hard surface Incorrect handling Damage to the pressure Contact Parker - replace Lifting system not conform to damaged components envelope, loss of integrity bowl weight and not safety Seal / closure face is...
10 Appendix Appendix 1 PHP03/05/08 ( Figure 9 Remove the filter bowl from the head and place both parts on a suitable surface where they may not be damaged a) Assemble the adjustable feet to the support legs (1) b) Screw the support legs (2) into the locations on the under side of the head (3 x positions). Adjust the feet (1) ensuring the housing is installed level.
Page 18
Appendix 2 PHP 12/18/24/30 ( Figure 11 a) Remove the filter bowl from the head and place both parts on a suitable surface where they may not be damaged b) Assemble the adjustable feet to the support legs (1) Screw the support legs (2) into the available locations on the under side of the head. d) Adjust the feet (1) ensuring the housing is installed level.
Page 19
Appendix 3 PHL 03/05/08 (Figure 14) a) Remove the filter bowl from the head and place both parts on a suitable surface where they may not be damaged b) Assemble the adjustable feet to the support legs (1) Screw the support legs (2) into the available locations on the under side of the head (3 positions) d) Adjust the feet (1) ensuring the housing is installed level.
Page 20
Appendix 4 PHW03/05/08 ( Figure 17 a) Remove the filter bowl from the head and place both parts on a suitable surface where they may not be damaged b) Fit the adjustable legs (1), 3 off, using the provided washer (2) and nuts (3). Adjust the feet (1) ensuring the housing is installed level.