Intelbras 8000 Series User Manual

Intelbras 8000 Series User Manual

Wireless alarm
Hide thumbs Also See for 8000 Series:

Advertisement

Quick Links

English
User manual
AMT 8000 LITE
AMT 8000 PRO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Intelbras 8000 Series

  • Page 1 English User manual AMT 8000 LITE AMT 8000 PRO...
  • Page 2 2 IPs (monitoring companies), 2 telephone numbers (monitoring company) plus the Intelbras Cloud connection, initially using the random remote access password indicated together on the QR Code label that also contains the MAC.
  • Page 3 » Perform periodic tests on it, in order to validate weather conditions, battery level and other factors, so that the site monitored by the system is always able to operate correctly. » LGPD - General (Personal) Data Protection Regulation: Intelbras does not access, transfer, capture, or carry out any other type of personal data processing from this product.
  • Page 4: Table Of Contents

    Summary 1. Technical specifications 2. Features of the alarm centers, AMT 8000 LITE and AMT 8000 PRO 3. AMT 8000 LITE and AMT 8000 PRO Accessories 3.1. GPRS module XG 2G, GSM XG 3G and GSM XG 4G ..........7 3.2.
  • Page 5 6.22. System reset ................83 6.23.
  • Page 6: Technical Specifications

    ( Stand by mode - continuous). ² Optional devices: FXO 8000 module compatible only with the AMT 8000 PRO model, for more information, consult the website www.intelbras.
  • Page 7: Features Of The Alarm Centers, Amt 8000 Lite And Amt 8000 Pro

    XG 4G module. » External antenna with 0 dBi gain. » Reports events to 2 IP destinations (monitoring company) plus the Intelbras cloud. » Connections with DNS destinations. » Power supply from the AMT 8000 LITE or AMT 8000 PRO alarm center.
  • Page 8: Communication Module Via Telephone Line - Fxo 8000

    The following figure presents an illustrative image of the XG 2G, XG 3G and XG 4G modules: GPRS module XG 2G, GSM XG 3G and GSM XG 4G Obs.: XG 2G, XG 3G and XG 4G modules are compatible with most national GPRS / GSM operators with 2G, 3G and 4G technology.
  • Page 9: Installation Of The Alarm Center And Its Peripheral Devices

    4. Installation of the alarm center and its peripheral devices Attention: only connect the central to the mains and battery after installing all the equipment and peripheral devices. Open the product box and then open the alarm center cabinet cover by removing the screws, where you will be able to see two plates, that is, its basic configuration contains the AMT 8000 LITE or AMT 8000 PRO alarm center plate and its respective power supply and the rechargeable battery that comes with the alarm center.
  • Page 10 1. Tamper-proof switch. 2. Integrated siren. 3. Connector for AC power. Caution: be careful not to invert the position of the ground wire. Attention: the AMT 8000 LITE and AMT 8000 PRO alarm control panels do not have an auxiliary output to power other devices and no connection point on the control panel boards (control panel or source) should be used for this functionality, as in addition to damaging the alarm control panel and its accessories, it may damage the devices that are connected because the alarm panels operate with different voltages.
  • Page 11: Alarm Center Power Supply (Full Range 90 And 265 Vac)

    4.1. Alarm center power supply (full range 90 and 265 Vac) The alarm center is equipped with a full range switching power supply that works with input voltages of 90 and 265 Vac without the need for a voltage selector switch. In this way, even if there is some voltage variation in the electrical network, the alarm center will continue to function normally (as long as the voltage is in the range of 90 to 265 Vac).
  • Page 12: Xg 2G/Xg 3G/Xg 4G Module

    The alarm centers have protection against inversion of polarity and short circuit in the battery and protection to prevent the battery from being damaged in the event of a failure in the electrical grid (if the battery voltage is below 2.8 V, the control unit will turn off so as not to damage the battery).
  • Page 13: Amt 8000 Lite And Amt 8000 Pro Alarm Center

    4.5. AMT 8000 LITE and AMT 8000 PRO alarm center The AMT 8000 LITE and AMT 8000 PRO alarm centers have an integrated wired siren, tamper switch against violation, and if the tamper switch is opened/violated, the integrated siren plus the registered sirens will go off and send the corresponding event if the function Problems that generate trigger is enabled (see section Problems that generate trigger ).
  • Page 14: Partitioning

    GPRS XG 2G/ XG 3G board LEDs Status/event Signaling LED1, LED2 Power supplied (on on the CPU board) LED1 and LED 2 constantly accessed Chip (SIM1 or SIM2) looking for LED1, LED2 Only the corresponding accessed LED connection LED blinking once (connected to server 1), LED1 Chip 1 (SIM1) connected to servers LED blinking twice (connected to server 2)
  • Page 15 Obs.: » If there is a mistake in entering the password, press the Back key and enter the password again. » When the control panel or partition receives the command to activate and any of the zones is open, a fault/error will be generated (long beep on keypads) and it will only be possible to activate the control panel when all zones are closed in the case of a complete or non-partitioned system , or in the case of partitioned systems with the zones of the respective partitions closed.
  • Page 16: Menu

    Obs.: only master password and passwords with permission to enable Partial mode enabled can activate the system in Partial mode. Deactivation by master password or full password If you are using the master password or a full password (which has permission to activate/deactivate all partitions), there are two forms of deactivation: »...
  • Page 17 Open sensors In normal operation mode, the XAT 8000 keyboard will display the status of the alarm center and if there are any open zones. To view currently open zones, press the Menu key and then access Open sensors and press the Enter key. Outside the programming mode, if 1 + Enter is pressed, zones 1 to 10 will be displayed.
  • Page 18 See the section Connections to define addresses of priorities and routings. » Cloud: will display if the alarm center is connected to the Intelbras Cloud server via ETHERNET or 2G/3G/4G. This server allows communication between the alarm centers and the remote access via application.
  • Page 19: Remote Update

    Address MAC It will display the MAC address of the alarm center. The MAC address will display with 12 digits between numbers and letters. Through this address the alarm center will connect to on-line on-line servers . Alarm center version It will display the alarm center version.
  • Page 20: Programming Mode

    Access to the alarm center via AMT Remote Mobile To execute the access via AMT Remote Mobile, select the Local IP connection option and enter the IP 192.168.4.1 plus the remote access password available on the QR Code label (EX: 878787). Access to the alarm center via Desktop programmer software To access via Desktop software, on the client's editing screen, enter the IP 192.168.4.1 in the option IP address for connection via ethernet/wi-fi plus the remote access password available on the QR Code label (EX: 878787).
  • Page 21 Wi-Fi provisioning enabled (function available for AMT 8000 PRO). For more information about the AMT Remote Mobile application, access the link http://www.intelbras.com. Obs.: it is necessary for the computer/remote access password to be enabled, see section 6.9. Passwords.
  • Page 22: Wireless Devices (Register/Delete)

    It is necessary that the alarm center is connected to the internet via Ethernet connection, GPRS/GSM (XG 2G, XG 3G or XG 4G module added to the alarm center is required) or Wi-Fi provisioning is enabled (function available for AMT 8000 PRO). Using the Intelbras Guardian application (for mobile devices) Through the application installed on a mobile device (smartphone/tablet – Android ®...
  • Page 23 Wireless device registration using the control unit’s synchronization button Press and release the alarm center synchronization key, LED 3 will light up continuously, indicating that the center is re- ady to register wireless devices. When completing the registration of all devices, press the alarm center synchronization button again and check that LED 3 has left Continuous mode (flashes indicating normal operation), showing that the control center has exited wireless device registration mode .
  • Page 24 » Remote controls (addresses 00 to 97): with the control to be registered in hand, enter the code below on the keyboard and press any of its keys. The control addressing takes place according to the command entered, respecting the maximum limit of 97 devices. To register remote controls, type: 00 to 97 Enter...
  • Page 25 a failure and the process must be repeated. Actuator addressing will take place according to the command performed, respecting the maximum limit of 16 devices of this type and after registration, all will be added to the common partition. To change the partition of the actuators, refer to the section PGM Partition . Obs.: so that the actuator activates the Relay, it must be supplied with a power of 12 to 24 Vdc or it must be connected in the 110/220 Vac AC network.
  • Page 26 Ex.: sensor 01 communicating directly with the alarm center. Ex.: sensor 01 communicating with repeater 01: Route change by command Attention: all devices, including the REP 8000 repeater, must be in version 2.0.0 or higher. For devices with a lower version, the route change prevails by restarting the devices.
  • Page 27: Wireless Sensor Functions

    Example: if a sensor that is communicating directly with the alarm center is without communication for 30 minutes, the sen- sor starts a new route search, and when receiving the first response, either from the alarm center itself or from one of the 4 repeaters, the device starts to follow that route forever or until it goes another 30 minutes without communication on that new route.
  • Page 28 Zone tamper detection To program this function, type: Command to disable the tamper of the sensors: Enter Enter X = Group zones 0 to 6 Command to disable the digital tamper of IVP 8000 EX Enter Enter X = Group zones 0 to 6 Obs.: function available from version 2.0.0 of the sensor.
  • Page 29: Remote Control Key Functions

    Test example with non-partitioned alarm center sensor 01: » 1 display line: The message P00 Located will be displayed » 2 display line: The message Sensor 01 will be displayed Obs.: for a partitioned system, P00 will be displayed for the common partition or P01 to P16 according to the partition the device belongs to.
  • Page 30 Use the following table to fill in the Function field to define functions for the remote control keys. Disabled Activate / Deactivate all partitions Activate only all partitions Deactivate only all partitions Activate / Deactivate all partitions in Partial mode Only assemble in Partial mode Panic with siren Silent panic...
  • Page 31: Wireless Keyboard Functions

    PGM 11 PGM 12 PGM 13 PGM 14 PGM 15 PGM 16 Key 1 Key 2 Key 3 To program this function, type: Enter Control key User Function Enter Table above 1, 2 or 3 00 to 97 From 00 to 66 To edit/view the programmed value, type: Enter Control key...
  • Page 32 Obs.: » All keyboards leave the factory programmed for common partition 00. » Even though the keyboard is partitioned, specific passwords are required to perform partition functions through it. » A keyboard can be registered in a single partition or be common to all, but a partition can have more than one keyboard (keyboards 01 to 16).
  • Page 33: Siren Functions

    Panic Key If the Panic key is pressed for 3 seconds, the siren will sound and the Audible Panic event will be reported to the monitoring company. This key can assume the following configurations: Function Selection Disabled Audible panic Silent panic Fire panic Medical emergency To program this function, type:...
  • Page 34 To edit/view the programmed value, type: Enter Siren Enter 1 to 16 After entering the command, define which partition the XSS 8000 siren will belong to, with address 00 being common (the siren will be triggered if an event is generated in any of the partitions) or from 01 to 16 (the siren will only be triggered if the partition it was defined for, generate some event) according to the desired partition and press the Enter key to confirm.
  • Page 35 After entering the command, through the XAT 8000 keyboard, mark which partitions will have the siren beep activated, using the keyboard numbers to leave them marked refering to the partition. Select 0 for partition group from 1 to 10 and 1 for partitions from 11 to 16.
  • Page 36 System activation: » Non-partitioned alarm center: activates the PGM output when the alarm center is activated. » Partitioned alarm center: activates the PGM output only with the activation of the partition to which the PGM belongs. If the PGM is common it will be activated with the activation of all partitions and deactivated with the deactivation of any partition.
  • Page 37 For example: it can activate a fire fighting system, activate a differentiated siren, activate emergency lights, etc. Opening of zone 1: » Non-partitioned alarm center: whenever zone 1 is opened, the PGM will be turned on (for presence sensors, the PGM will be activated and deactivated whenever there is a detection and for opening sensors, the PGM will be activated on opening and deactivated on closing or after a time programmed if the sensor remains open).
  • Page 38 Scheduled time Configure the time in minutes that the PGM will remain activated. To program this function, type: 1 to 99 Enter Enter Time 1 to 16 To edit/view the programmed value, type: Enter Enter 1 to 16 After changing the configured value, press the Enter key. If you only want to view the configuration, press the Exit key and no programming will be changed.
  • Page 39 Use the keyboard keys to define the days for the automatic deactivation of the PGM to occur, so that the referring numbers, who wish to have the days enabled, remain marked and the days with the function disabled remain unmarked and then confirm with the Enter key.
  • Page 40: Update

    To program this function, type: 00 to 16 Partition no. Enter Enter 1 to 16 To edit/view the programmed value, type: Enter Enter 1 to 16 After changing the configured value, press the Enter key. If you only want to view the configuration, press the Exit key and no programming will be changed.
  • Page 41 » If the alarm center is operating with a 4-digit password, no password can be equal to the first 4 digits of the remote access password. » » If the switchboard system is reset, it will no longer use the random passwords that are linked together with the QR Code label pasted inside the switchboard and will use password 1234 as the master password and password 878787 as access remote until they are changed again.
  • Page 42 User group Users from User group Users from User group Users from (GU) 31 to 40 (GU) 41 to 50 (GU) 51 to 60 Key 1 = user 31 Key 1 = user 41 Key 1 = user 51 Key 2 = user 32 Key 2 = user 42 Key 2 = user 52 Key 3 = user 33...
  • Page 43 Programming of passwords using the master password Change the passwords using the master password With the master password it is possible to change the master password itself, register secondary passwords (master password - 00, secondary users - 01 to 96, duress password - 97). Attention: users 51 to 66 are dedicated to the PGM, therefore these users will have the same permissions as the other secondary users, but if the PGM is registered in the alarm center and the PGM is configured to be activated by a password, the password will have exclusivity for PGM.
  • Page 44: Quick Configurations For Monitoring

    Permission to only activate or permission to bypass From 0 to 9 User group Password permission Enter Enter 5 = only activates 6 = bypass Use the keys on the keyboard to enable the permissions to only activate and bypass for users from positions 01 to 96, so that the corresponding numbers that you want to have the function enabled remain marked on the display and then confirm with the Enter key.
  • Page 45 Monitoring via Ethernet/Wi-Fi (Wi-Fi only for AMT 8000 PRO alarm center) The alarm center can report events via IP communication to monitoring companies (Intelbras IP Receiver Software), for which the following commands must be programmed: If you are using Wi-Fi connection before setting the monitoring options, program the following commands: Obs.: the alarm center is connected only with 2.4 GHz routers.
  • Page 46 » Program DHCP If you do not have a DHCP server or do not want to use this option, do not enable it and follow the next steps, where network mask, gateway, etc. will be added manually and not received from the connected network. Enter + 831 + Enter After the command, using the keyboard keys, enable option 1 (mark 1) and press the Enter key to confirm.
  • Page 47 » Program destination domain name (DNS) If you do not want to use DNS move to the next command, otherwise, type. Enter + 803 + D + Enter , where D = 1 or 2 (DNS 1 or DNS 2). After the command, type the DNS domain name and press the Enter key to confirm.
  • Page 48: Configurations Of Zones

    6.12. Configurations of zones Zone configurations can be performed to adapt/define functionalities that best fit the alarm center operating environment. The following table demonstrates which group the zone is in, divided into 10 and the keyboard keys referring to each zone, according to the chosen group.
  • Page 49 To program, type: From 0 to 6 Zone group Enter Enter Use the keys on the keyboard to define which zones will have Parcial mode, so that the referring numbers, who wish to have the zone with Parcial, mode, remain marked and the zones without the function remain unmarked and then confirm with the Enter key.
  • Page 50 Use the keyboard keys to define the function of the zone, so that the referring numbers, who wish to have the zone with the given function, remain marked and the zones without the function remain unmarked, then confirm with the Enter key. Obs.: each zone can have only one function and if programming is done in a zone already configured with another function, the last programming made will remain as operative Zone operating mode...
  • Page 51: Program The Partitioning Of The Alarm Center

    To edit/view the programmed value, type: Enter Enter After changing the configured value, press the Enter key. If you only want to view the configuration, press the Exit key and no programming will be changed. Entry on partition Choose the partition that will be activated or deactivated through the On entry, factory default all partitions are enabled. For a non-partitioned system, keep at least partition 01 enabled.
  • Page 52: Timings

    To edit/view the partition of programmed zones, enter: From 01 to 64 Zone Enter Enter After changing the configured value, press the Enter key. If you only want to view the configuration, press the Back/Exit key and no programming will be changed. Obs.: if zones are not defined for the partition, it will be inactive.
  • Page 53 To edit/view the programmed value, type: Enter Enter Partition 1 to 16 After changing the configured value, press the Enter key. If you only want to view the configuration, press the Exit key and no programming will be changed Adjustment of the beep in entry timing To program this function, type: Enter Volume adjustment...
  • Page 54: Alarm Center Time Configurations

    Disable output beep This function allows you to disable only the output time beeps that are emitted by wireless keyboards (beeps are only emitted when the time is different from zero). To program this function, type: Enter Enter After entering the command, use key 8 to mark/enable this function and then confirm with the Enter key. If you only want to view the configuration, press the Back/Exit key and no programming will be changed.
  • Page 55 Time interval for synchronization of date and time When this function is enabled, the alarm center will synchronize the date and time with the server where the Intelbras IP Receiver software is installed (factory default 24-hour synchronization), for third-party software, they must be consulted. Syn- chronization will occur in the following situations: »...
  • Page 56: Time Zone

    6.16. Time zone When the alarm center is programmed to synchronize the date and time automatically, programming this field adjusts the time zone according to the region where the switchboard is installed. Time zone ranges from 00 (disabled) to 25, where 01 means GMT -1, 02 means GMT -2, and so on.
  • Page 57: Periodic Test

    6.17. Periodic test This function is used to verify the integrity of the communication channel between the alarm center and the monitoring company. If programmed, the Periodic test event will be periodically reported. Thus, if the monitoring company does not receive this event within the scheduled period, the communication channel can be considered inoperative.
  • Page 58 Obs.: for adjustment of the day of the week, consult the programming in the topic 6.13. Alarm center time configura- tions. 6. If you want to enable the automatic synchronization of date and time with the server (make sure that the latest version of Intelbras Receiver IP is being used so that the function takes effect correctly).
  • Page 59 Use the following table referring to the following necessary programmings: Day of the week Key 1 Sunday Key 2 Monday Key 3 Tuesday Key 4 Wednesday Key 5 Thursday Key 6 Friday Key 7 Saturday Key 8 Holiday Selection of automatic activation / automatic deactivation by partitions Selects which partitions will have the programmed automatic activation and automatic deactivation function.
  • Page 60 To edit/view the programmed value, type: 1 to 8 Enter Enter Partition 1 to 16 After changing the configured value, press the Enter key. If you only want to view the configuration, press the Back/Exit key and no programming will be changed Days of the week for Automatic deactivation Select the days when Automatic deactivation by partition will occur.
  • Page 61: Monitoring Configurations

    For the correct operation of this function, it is necessary to check whether the following scheduled automatic activation and automatic deactivation programmings are correctly enabled: » Days for programmed automatic activation. » Time of programmed automatic activation. » Days for programmed automatic deactivation. »...
  • Page 62 Contact-ID Events The alarm center leaves the factory with all events enabled (default Contact-ID). See below the list of Contact-ID events. Event Standard code Medical emergency Fire alarm Panic Activation and deactivation under filtration Silent panic Zone trigger / zone restoration 24-Hour zone trigger Silent trigger AC network failure / AC network restoration...
  • Page 63 Enable / disable events As it can be observed in the following commands, the event can be blocked if it is configured as 000 (it will not be sent to the Receiver IP) and enabled when registering FFF (it will be sent to the Receiver IP) The tables below show the events and the respective default Contact-ID codes.
  • Page 64 User no. Enter Enter 1 to 97 Restoration type events Activation by user User no. Event Contact-ID Code 1 to 97 Activation by user User no. Enter Enter 1 to 97 Opening type events  System events  Table of Contents Internal event Standard code Low battery wireless device Supervision failure...
  • Page 65 00 to 24 Push Events Notifications that will be sent to the Intelbras Guardian application when the corresponding event occurs with the alarm center, and it is necessary that the alarm center is connected to Internet (Ethernet, 2G/3G or 4G).
  • Page 66 BATEIRA_BAIXA_SENSOR (Low_Battery_Sensor), Key 1 Enabled Key 2 Enabled FALHA_SUPERVISAO_RF (RF_Supervision_Failure), Key 3 Enabled BYPASS_ZONA (Zone_Bypass), Key 4 Enabled BYPASS_AUTOMATICO (Automatic_Bypass), Key 5 Enabled FALHA_REDE_ELETRICA (Electric Grid_Failure), Key 6 Enabled BATERIA_PRINCIPAL_BAIXA (Low_Main_Battery), Key 7 Enabled BATERIA_PRINCIPAL_AUSENTE (Main_Battery_Absent), Key 8 Enabled Key 9 Enabled ARME_DESARME_REMOTO (Remote_Assembly_ Disassembly),...
  • Page 67 Reporting mode The alarm center can be configured to report events to the monitoring company, through one of the modes describe below: » Deactivated: in this mode the alarm center will operate as a monitored alarm center, not reporting the events of the occurrences through no channel, only to applications, if used.
  • Page 68 To edit/view the programmed value, type: Enter Memory no. Enter 1 to 8 After changing the configured value, press the Enter key. If you only want to view the configuration, press the Exit key and no programming will be changed To erase a previously programmed phone, type: Enter Memory no.
  • Page 69 The alarm center, when connected via Wi-Fi, can also be accessed remotely through Intelbras applications. For the alarm center to be connected to a Wi-Fi network, the following commands must be executed:...
  • Page 70 After entering the command, use the XAT 8000 keyboard keys to enter the name of the network you want to connect, paying attention to special characters if applicable and after changing the value, press the Enter key. If you only want to view the configuration, press the Exit key and no programming will be changed Obs.: check if the network to be connected has special characters, numbers and different symbols in its name, which if not inserted can prevent the connection to the correct network.
  • Page 71 IP2) can be programmed, regardless of whether the communication channel used is Ethernet, WI-FI or GPRS, the report will be made to the same addresses. To receive events over the Internet, it is necessary to install the Intelbras IP Receiver software on the computer or use a monitoring software already compatible with the TCP/IP communication of the AMT 8000 LITE and AMT 8000 PRO alarm centers.
  • Page 72 The port is a number associated and mandatory to communication sections between applications in IP networks. This field defines the port to which the alarm center will connect, factory default 9009 . Intelbras IP Receiver software must be configured to the same port. Some ports may be used by other applications, so choose one that is free, preferably above 1000.
  • Page 73 The following options configure the network properties on the alarm center, such as IP address, mask, gateway, etc., very similar to the configurations of a network card on a computer. These configurations allow the alarm center to connect to the Intelbras IP Receiver software and transmit events. Visualization of the alarm center MAC To view the alarm center MAC, perform the following procedure: 1.
  • Page 74 Network mask (connection by cable) To view/edit the network mask of the alarm center, type: 8130 Enter Enter The current network mask will be shown, being the factory default 255.255.255.000 , to insert/change the mask, type the new programming and press Enter key to confirm the programming. If you only want to view the configuration, press the Back/Exit key and no programming will be changed.
  • Page 75 To check if the communication between the alarm center and the Intelbras Receiver IP software is working, the alarm center will send a message (known as Heartbeat or Keep alive) according to the programmed time interval. If the Intelbras IP Receiver does not receive this message within the programmed time interval, a fault event may be generated.
  • Page 76 Login Login for connection in the 2G/3G network of the operator used. This field accepts letters and numbers and can contain up to 16 digits. The default logins for some operators are listed below. Operator Login Claro claro Vivo vivo Obs.: this information can be changed with no prior notice.
  • Page 77 With the same function as the Ethernet Heartbeat Interval (link test), but relative to the GPRS channel. To check if the communication between the alarm center and the Intelbras Receiver IP software is working, the alarm center sends a message (known as Heartbeat or Keep alive) according to the programmed time interval. If the Intelbras IP Receiver does not receive this message within the programmed time interval, a fault event may be generated.
  • Page 78 Interval between GPRS connection attempts When there is a failure in the cellular modem connection (XG 2G or XG 2G) with the Intelbras IP Receiver software, the alarm center tries to make a new connection with it. This function will define the time between these attempts and it leaves the factory at zero (00 minutes).
  • Page 79: Activation/Deactivation Of Functions

    To program this function, type: Maximum 20 digits Memory no. Phone no. Enter Enter 1 to 5 Obs.: type the telephone number to be programmed, starting with the area code, then the operator and finally the number always starting with the digit 9 (nine) – if it is a cell phone – followed by another 8 (eight) numbers. Example: Position Number with...
  • Page 80 » Siren beep during activation / deactivation: activates / deactivates the beep emitted by the siren during activation / deactivation of the alarm center. During activation, the siren will emit a short beep and during deactivation, the siren will emit short beeps. If a problem is detected and the Siren Problem Indication function is enabled, a long beep will be emitted on activation and two long beeps on deactivation.
  • Page 81 Maintenance order by Enter key Problem indication by siren Automatic cancellation due to opening of zone Use the keyboard keys to define the status of the function, so that the referring numbers, who wish to have the function active, remain marked and the functions that should remain inactive remain unmarked, then confirm with the Enter key. Blocks The parameters configured in this group of functions are described below: »...
  • Page 82: Time For Sending Of Ac Failure

    To program this function, type: Enter Enter Function Real time reporting Disables exit time beep Use the keyboard keys to define the status of the function, so that the referring numbers, who wish to have the function active, remain marked and the functions that should remain inactive remain unmarked. Problems that generate trigger With this function enabled, sirens will go off if at least one of the following events is detected: supervision failure, device tampering, in addition to system intrusions.
  • Page 83 To program this function, type: Enter Time Enter 01 to 99 minutes To edit/view the programmed value, type: Enter Enter After changing the configured value, press the Enter key. If you only want to view the configuration, press the Exit key and no programming will be changed 6.22.
  • Page 84 Provisioning Enable provisioning by synchronism button Press the wireless device registration key for 7 seconds, the LED will start flashing quickly to indicate that the alarm center is in provisioning mode and this mode will remain for 5 minutes, if not performed. access to the alarm center it will cancel provisioning and return to normal operation, if there is a connection to the alarm center it will remain in provisioning mode until the remote connection is terminated by the user.
  • Page 85 » Change messages Enter + GM + Activates + (User, device, partition or zone) + Enter GM = group of messages from 1 to 8. User, device, partition or zone = in the case of messages for zone 1 to 64, device from 01 to 16, partition from 01 to 16 and in the case of user from 00 to 99.
  • Page 86 Activate / Deactivate Partition 4 only Activate / Deactivate Partition 5 only Activate / Deactivate Partition 6 only Activate / Deactivate Partition 7 only Activate / Deactivate Partition 8 only Activate / Deactivate Partition 9 only Activate / Deactivate Partition 10 only Activate / Deactivate Partition 11 only Activate / Deactivate Partition 12 only Activate / Deactivate Partition 13 only...
  • Page 87 » Adjustment of wireless infrared sensors Attention: settings available for devices with firmware version lower than 3.0.0. For equal or higher versions consult the device manual for more information. Enter + 66 + ZZ + S + L + M + Enter ZZ = zone from 01 to 64 S = Sensitivity from 0 to 3, where 0 = Minimum Sensitivity / 1 = Normal Sensitivity / 2 = Intermediate Sensitivity / 3 = Maximum Sensitivity Maximum.
  • Page 88 » Register Range RF Amplifier (REP 8000 repeater) Enter + 622 + NA + Enter + Activate the amplifier by pressing the synchronization key NA = amplifier number from 01 to 04. » Turn off Range RF Amplifier (REP 8000 repeater) Enter + 722 + NA + Enter NA = amplifier number from 01 to 04.
  • Page 89 » Time for Automatic Activation of PGM 8000 Actuator Enter + 561 + PGM + D + HH + MM + Enter PGM = PGM number from 01 to 16. D = day of the week from 1 to 7 (1 = Sunday, 2 = Monday, 3 = Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, 7 = Saturday and 8 for holidays).
  • Page 90 Obs.: it is necessary that the alarm centers are connected to the Internet through Ethernet or Wi-Fi connection. It is not possible to download/update software through the GPRS connection due to the connection download rate and excessive consumption of the package used. Passwords »...
  • Page 91 » Zone functions Enter + 3 + F + G + Enter F = functions of zones from 1 to 6. G = zone group from 0 to 6 After inserting the command, through the keyboard keys enable / disable the zones corresponding to the group and press the Enter key to confirm.
  • Page 92 Attention: in addition to the aforementioned programming points, it is necessary that the user passwords are created / defined (topic Passwords ), the registration of wireless controls for access (topic Wireless controls ) and the definition of the partitioning of keyboards (topic Keyboards ) and sirens (topic Wireless sirens ). Timings »...
  • Page 93 08 - GMT -8 09 - GMT -9 10 - GMT -10 11 - GMT -11 12 - GMT -12 13 - GMT 0 14 - GMT +1 15 - GMT +2 16 - GMT +3 17 - GMT +4 18 - GMT +5 19 - GMT +6 20 - GMT +7...
  • Page 94 » Automatic Activation Time Enter + 462 + PP + D + HH + MM + Enter PP = partition from 01 to (non-partitioned center, use PP = 01) D = day of the week from 1 to 7 (1 = Sunday, 2 = Monday, 3 = Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, 7 = Saturday).
  • Page 95 P = port that will be used for the alarm center to connect, where 1 = port 1 and 2 = port 2. After the command, insert the port number with 4 digits. Obs.: this field defines the port to which the alarm center will be connected, factory standard: 9009 . Intelbras IP Receiver software must be configured to the same port.
  • Page 96 » Program DHCP If you do not have a DHCP server or do not want to use this option, execute the next option, otherwise, type the following command and also the next ones. Enter + 831 + Enter After the command, using the keyboard keys, enable option 1 (mark 1) and press the Enter key to confirm. »...
  • Page 97 » Program the PIN (Personal Identification Number) If you want to use the PIN, perform the command in sequence, otherwise proceed with the next command. If the PIN is incorrect, the chip will be blocked. Enter + 825 + O + PIN Number with 4 digits + Enter , where O = 1 or 2 (operator 1 or operator 2) »...
  • Page 98 Opening type events System events Table of Contents Internal event Standard code Low battery wireless device Supervision failure Zone bypass AC network failure Low system battery Battery absent Remote deactivation Automatic deactivation System reset Programming change Failure when communicating event Incorrect password Remote access Manual testing...
  • Page 99 Tamper of expander devices Sensor tamper AC failure wireless device PGM activation » Configure event code Push Enter + 92 + EV + Enter + Select the event + Enter EV = event group from 0 to 3, where group 0 is from 01 to 10 and so on, up to group 3 which is from 31 to 35. Event group Event (EV)
  • Page 100 RESET_BUFFER_EVENTOS ()Event_Buffer_Reset) Key 1 Enabled RESET_DATA_HORA Date_Time_Reset) Key 2 Enabled Key 3 Enabled TAMPER_SIRENE (Tamper_Siren) Key 4 Enabled SOLICITACAO_MANUTENCAO (Maintenance_ Enabled Request) Key 5 FALHA_REDE_ELETRICA_MOD_EXPANSOR Enabled (Electric_Grid_Failure_Expander_Module) Key 6 ACTIVATION / DEACTIVATION_PGM Key 7 Enabled RF REGISTRATION / EXCLUSION Key 8 Enabled REGISTRATION / CHANGE / EXCLUSION OF Enabled...
  • Page 101 Time of sending of failures » AC failure Enter + 481 + TM + Enter TM = time of sending of the failure from 01 to 99 minutes. System reset » Reset of the entire system except registration of wireless devices Enter + 0000 + Enter »...
  • Page 102 7. Intelbras is not responsible for the installation of this product, and also for any attempts at fraud and/or sabotage in its products. Keep software updates and applications used up to date, if applicable, as well as the necessary network protections to protect against intrusions (hackers).
  • Page 103 Support via e-mail: suporte@intelbras.com.br Customer Service: 0800 7042767 Where to buy? Who installs it? 0800 7245115 Produced by: Intelbras S/A – Indústria de Telecomunicação Eletrônica Brasileira Rodovia BR 459, km 124, 1325 – Distrito Industrial – Santa Rita do Sapucaí/MG – 37540-000 03.23 CNPJ 82.901.000/0016-03 –...

This manual is also suitable for:

Amt 8000 liteAmt 8000 pro

Table of Contents