Pickering 40-519B User Manual

Pickering 40-519B User Manual

Pxi 2 amp 2-pole matrix module

Advertisement

Quick Links

40-519B User Manual
PXI 2 Amp 2-Pole Matrix Module
pickeringtest.com
Issue 1.0 March 2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 40-519B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pickering 40-519B

  • Page 1 40-519B User Manual PXI 2 Amp 2-Pole Matrix Module pickeringtest.com Issue 1.0 March 2021...
  • Page 2 © COPYRIGHT (2021) PICKERING INTERFACES. ALL RIGHTS RESERVED. No part of this publication may be reproduced, transmitted, transcribed, translated or stored in any form, or by any means without the written permission of Pickering Interfaces. Technical details contained within this publication are subject to change without notice.
  • Page 3 Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment. Pickering Interfaces aims to design and operate products in a way that protects the environment and the health and safety of its employees, customers and the public. Pickering Interfaces endeavours to develop and manufacture products that can be produced, distributed, used and recycled, or disposed of, in a safe and environmentally friendly manner.
  • Page 4: Product Safety

    To indicate that static sensitive devices are Pour indiquer que des appareils sensibles present and handling precautions should be statiques sont présents et les précautions de followed. manipulation doivent être suivies. 2 A 2-POLE MATRIX MODULE 40-519B REED RELAY MODULE 40-110/115/120/125 Page (IV) Page (IV)
  • Page 5: Table Of Contents

    Pre Operation Checks ............3.1 Hardware Installation ............3.1 Software Installation .............3.3 Testing Operation ..............3.4 Section 4 Programming Guide ..............4.1 Programming Options For Pickering PXI Modules ....4.1 Module Architecture ..............4.2 Programming The Module ............4.3 Section 5 Connector Information ..............5.1 Section 6 Trouble Shooting .................6.1 Section 7 Maintenance Information ............7.1...
  • Page 6 THIS PAGE INTENTIONALLY BLANK 2 A 2-POLE MATRIX MODULE 40-519B Page (VI)
  • Page 7: Warnings And Cautions

    Blanking panels are signaux d’E/S utilisateur qui peuvent être présents. available to order from Pickering in a variety of slot Les obturateurs sont disponibles sur commande chez widths. If the product is not used in this manner for Pickering dans une variété...
  • Page 8 “arrêt an emergency press the red “emergency stop” d’urgence” situé sur l’avant de l’unité. button situated on the front of the unit. GENERAL PURPOSE 2A RELAY MODULE 40-131/132 Page (VIII) 2 A 2-POLE MATRIX MODULE 40-519B Page (VIII)
  • Page 9: Technical Specification

    The 40-519B is part of Pickering’s family of High Density, 128 crosspoint, BIRST enabled EMR PXI The 40-519B is a 32x4 2-pole 2 A matrix module and is part matrices, the range is as follows: of our range PXI switching solutions.
  • Page 10 100 kHz 70 dB 1 MHz 60 dB 10 MHz 40 dB Power Requirements +3.3 V +5 V +12 V -12 V 0.3 A (Typical) 0.5 A (Typical) 0.1 A (Typical) pickeringtest.com 2 A 2-POLE MATRIX MODULE 40-519B Page 1.2...
  • Page 11 Please contact your local sales office to discuss. For further assistance, please contact your local Pickering sales office. Mating Connectors & Cabling For connection accessories for the 40-519B please refer to the 90-006D 78-pin D-type Connector Accessories data sheet where a complete list and documentation can be found for accessories, or refer to the Connection Solutions catalog.
  • Page 12 We provide a full range of supporting cable and connector solutions for all our switching products—20 connector families with 1200+ products. We offer everything from simple mating connectors to complex cables assemblies and terminal blocks. All assemblies are manufactured by Pickering and are guaranteed to mechanically and electrically mate to our modules. Connectors & Backshells...
  • Page 13 2 A 2-Pole Matrix, 40-519B Programming Pickering provide kernel, IVI and VISA (NI & Keysight) drivers which are compatible with all Microsoft supported versions of Windows and popular older versions. For a list of all supporting operating systems, please see: pickeringtest.com/os...
  • Page 14 SECTION 1 - TECHNICAL SPECIFICATION pickering THIS PAGE INTENTIONALLY BLANK 2 A 2-POLE MATRIX MODULE 40-519B Page 1.6...
  • Page 15: Technical Description

    PCI Bridge BIRST Relays Configuration RL129-130 Memory Module Terminating Configuration Buffers Memory U2-3 Relays RL1-128 Relay Drivers 32x4, 2-pole Matrix +12V U11-18 +3.3V Figure 2.1 - 40-519B Matrix Module: Functional Block Diagram 2 A 2-POLE MATRIX MODULE 40-519B Page 2.1...
  • Page 16 SECTION 2 - TECHNICAL DESCRIPTION pickering THIS PAGE INTENTIONALLY BLANK 2 A 2-POLE MATRIX MODULE 40-519B Page 2.2...
  • Page 17: Installation

    VII. à la Page VII. Ensure that there is adequate ventilation. Assurez-vous que la ventilation est adéquate. 2 A 2-POLE MATRIX MODULE 40-519B REED RELAY MODULE 40-110/115/120/125 Page 3.1 Page 3.1...
  • Page 18 9. For Pickering Interfaces modular LXI installation b. Pour un système comprenant plus d’un châssis, there is no requirement to use any particular power allumez le dernier châssis dans le système up sequence.
  • Page 19: Software Installation

    Si vous n’êtes pas un utilisateur de LabVIEW, vous LabVIEW Runtime Engine installer via the shortcut devez choisir la version “complète”, et une fois qu’elle on the Programs>>Pickering menu. In the absence of a été installée. Lancer le programme d’installation LabVIEW the Runtime Engine is required to support LabVIEW Runtime Engine via le raccourci dans the Pickering Test Panels application.
  • Page 20: Testing Operation

    Figure 3.2 - General Soft Front Panel Icon A selector panel will appear, listing all installed Pickering PCI, PXI or LXI switch cards and resistor cards. Click on the card you wish to control, and a graphical control panel is presented allowing operation of the card.
  • Page 21: Programming Guide

    SECTION 4 - PROGRAMMING GUIDE PROGRAMMING OPTIONS FOR PICKERING INTERFACES PXI MODULES For information on the installation and use of drivers and the programming of Pickering’s products in various software environments, please refer to the Software User Manual. This is available as a download from: https://www.pickeringtest.com/support/software-drivers-and-downloads...
  • Page 22: Module Architecture

    MODULE ARCHITECTURE The 40-519B is a two pole switching matrix with 128 crosspoints.Connections are made by operating the relays at the crosspoints between X and Y lines allowing single X-Y connections, or X-X connections using a Y line as a path.
  • Page 23: Programming The Module

    PROGRAMMING THE MODULE Using The IVI Driver, Direct I/O Driver or VISA Driver This section provides some code fragments which show how to control the 40-519B-002 Matrix using the IVI Driver, Direct I/O Driver or the VISA Driver. Once the drivers are installed the manual “Sys40Prg.pdf” and driver help files which fully describes these functions can be found in the Pickering folder(s) or the Pickering entries on your Start Menu.
  • Page 24 SECTION 4 - PROGRAMMING GUIDE pickering THIS PAGE INTENTIONALLY BLANK 2 A 2-POLE MATRIX MODULE 40-519B Page 4.4...
  • Page 25: Connector Information

    X31.1 X32.1 FP_GND Y1.1 Y2.1 Y1.2 Y2.2 Y3.1 Y4.1 Y3.2 Y4.2 Figure 5.2 - 2 Amp 2 Pole Matrix Module 40-519B-002 (32x4): Pinouts (78-pin Male D-type Connector Viewed From Front of Module) 2 A 2-POLE MATRIX MODULE 40-519B Page 5.1...
  • Page 26 SECTION 5 - CONNECTOR INFORMATION pickering THIS PAGE INTENTIONALLY BLANK 2 A 2-POLE MATRIX MODULE 40-519B Page 5.2...
  • Page 27: Trouble Shooting

    Mises en garde au début du manuel. INSTALLATION PROBLEMS PROBLÈMES D’INSTALLATION The Plug & Play functionality of Pickering switch cards La fonctionnalité Plug & Play des cartes de generally ensures trouble-free installation. commutation Pickering assure généralement une installation sans problème.
  • Page 28: Maintenance Information

    OUTILS DE TEST DE SYSTEME DE SWITCHING SYSTEM TEST TOOLS COMMUTATION Please refer to Section 7 - Maintenance Information Référez-vous à la Section 7 - Information sur l’entretien REED RELAY MODULE 40-110/115/120/125 2 A 2-POLE MATRIX MODULE 40-519B Page 6.2 Page 6.2...
  • Page 29 Pour les modules PXI qui sont pris en charge dans Pickering Interfaces’ Modular LXI Chassis (such l’un des châssis modulaire LXI de Pickering Interfaces as the 60-102B and 60-103B) no module software (comme le 60-102B et 60-103B) aucune mise à jour update is required.
  • Page 30: Relay Lookup Tables

    USING BIRST ™ (BUILT-IN RELAY SELF TEST) UTILISATION BIRST ™ (AUTOTEST INTÉGRÉ DE RELAIS) The Pickering Interfaces BIRST (Built-In Relay Self Test) Tool provides a simple means of testing selected L’outil d’autotest intégré de relais BIRST™ de Pickering Interfaces switching products, including...
  • Page 31 SECTION 7 - MAINTENANCE INFORMATION pickering TABLE 7.2 - 40-519B-002 Matrix Module: Relay Numbering 40-519B RELAY CROSS REFERENCE (32x4 MATRIX) Crosspoint Crosspoint Crosspoint Crosspoint Relay Relay Relay Relay 1.1 & 1.2 1.1 & 1.2 1.1 & 1.2 2.1 & 2.2 1.1 &...
  • Page 32 RL105 RL106 RL107 RL108 RL109 RL110 RL111 RL112 RL113 RL114 RL115 RL116 RL117 RL118 RL119 RL120 RL121 RL122 RL123 RL124 RL125 RL126 RL127 RL128 Figure 7.1 - 32x4 Matrix Module 40-519B-002: Component Layout 2 A 2-POLE MATRIX MODULE 40-519B Page 7.4...

Table of Contents