OVERVIEW
For the start-up of this device you require: Main unit by 2xAAA batteries
Sensor by 2xAAA batteries
MAIN UNIT
![BALDR - B0201WST2H2 - MAIN UNIT MAIN UNIT]()
LCD DISPLAY
![BALDR - B0201WST2H2 - LCD DISPLAY LCD DISPLAY]()
- Weather Forecast
- Outdoor Temperature
- Indoor Temperature
- Current Time
- Outdoor Sensor Channel
- Outdoor Humidity
- Indoor Humidity
- Calendar and Moon Phase
- Touch Buttons
OUTDOOR SENSOR
![BALDR - B0201WST2H2 - OUTDOOR SENSOR OUTDOOR SENSOR]()
FEATURES
- Indoor and outdoor temperature (ºC/ºF Selectable)
- Indoor temperature range: 0℃~50.0℃(14℉~122℉)
- Outdoor temperature range: -20℃~65℃(-4℉~149℉)
- Indoor and outdoor humidity range: 20%~95%
- Records max/min temperature and humidity (in and out)
- Weather forecast for 5 modes: Sunny, Sunny To Cloudy, Cloudy, Rainy, Stormy
- RF Channel For Outdoor Sensor
- Alarm and snooze function
- Time display in 12/24H
- White backlight lasts for 10 seconds after pressing the "Snooze/Light" button
- 100 meters wireless transmitter in open area
- Moon phase and calendar function
GETTING STARTED
MAIN UNIT INSTALLATION
- Remove the battery compartment cover.
- Insert 2x AAA batteries matching the polarity (+and-).
SENSOR INSTALLATION
- Remove the battery compartment cover.
- Insert 2xAAA batteries matching the polarity (+and-).
Initialize
After power on, LCD will full display for 1 second, and in the meanwhile hygrometer will detect indoor temperature & humidity, and then it will start to receive outdoor signal which lasts for max 3 minutes
Function / Operation | MEM/▼ | AL/SET | CH/▲ | SNOOZE / LIGHT |
Standard Time Mode | Press | Check Max/Min Record | Switch to Alarm Time Mode | Switch channel | Backlight on |
Hold | ------ | Enter Into Time Set Mode | RF re-registration | ----- |
Alarm Time Mode | Press | Alarm on/off | Switch to Standard Time Mode | Switch channel | Backlight on |
Hold | ------ | Enter Into Alarm Time Set Mode | RF re-registration | ----- |
Time Set Mode | Press | Decrease 1 step | Confirm and go next | Increase 1 step | Backlight on |
Hold | Decrease in 8 steps | ------ | Increase in 8 steps | ----- |
Alarm Time Set Mode | Press | Decrease 1 step | Confirm and go next | Increase 1 step | Backlight on |
Hold | Decrease in 8 steps | ------ | Increase in 8 steps | ----- |
Alarm Mode | Press | Alarm off | Alarm off | Alarm off | Snooze Function |
Hold | ------ | ------ | ------ | Alarm off |
TIME SET
- Press and hold "AL/SET" button to enter into time setting; the setting data will be flashing in 1Hz.
- Press "MEM/
" or "CH/
" button to adjust data; press and hold "MEM/
" or "CH/
" button will quickly change the data by 8 steps. - The setting order is: Year →Month →Day →Weekday Language →Time zone →12/24H →Hour →Minute →C/F → Exit.
- There are 7 languages selectable for weekday display: FR, NE, ES, DR, EN, GE, IT (French, Dutch, Spanish, Denish, English, German, Italian)
- If no operation for 20 seconds, it will automatically save and exit setting.
ALARM SET
- On normal time display mode, press "AL/SET" button to switch to alarm display mode.
- Press and hold "AL/SET" button to enter into alarm time setting mode.
- Press "MEM/
" or "CH/
" button to adjust data; press and hold "MEM /
" or "CH/
" button will quickly change the data by 8 steps. - The setting order is: Hour → Minute→ Exit.
- On alarm display mode, press the "MEM/
" button to turn on/off the alarm. - If no operation for 20 seconds, it will automatically save and exit setting.
ALARM AND SNOOZE
- When alarm is ringing, press "SNOOZE/LIGHT" button to activate snooze function. And the alarm will ring again in 5 minutes.
- Press and hold "SNOOZE/LIGHT" button for more than 3 seconds will stop the alarm; or press any other button to stop the alarm. And the alarm will restart next day.
- The ascending "Bibi" alarm sound will last for 2 minutes if no operation.
MAX AND MIN RECORD
- Press "MEM/
" to have maximum temperature and humidity, the value will display 5 seconds. - Press "MEM/
"second time to have the minimum temperature and hu midity, the value will display 5 seconds. - Press "MEM/
"third time will return to standard mode. - Press and hold "MEM/
" will clear the max and min record and reactivate the memory. - Normally, the Max and Min record will update every 24 hours on 0:00.
OUTDOOR CHANNEL
- Hygrometer will auto receive outdoor signal after power on, the receiving status will last for max 3 minutes, the receiving antenna signal will flash, if no signal received in 3 minutes, will not exist and stop receiving outdoor signal
- Press "CH/
" button to change the channel - The setting order is CH1 → CH2→ CH3 → Channel scan (from CH1 to CH2 to CH3, 10 seconds intervals)
- Press and hold "CH/
" button for more than 3 seconds to manually enter into RF re-registration, press and hold "CH/
" button for 3 seconds again will exit RF registration - The current outdoor temperature and humidity data will be cleared during re-registration status
- Remark: if hygrometer has received outdoor data successfully before, in next 60 minutes if lost signal, the hygrometer outdoor area will display "--.--"
WEATHER FORECAST
The weather forecast icon will show after power on. There are 5 kinds of weather modes: Sunny, Sunny To Cloudy, Cloudy, Rainy, Stormy. The weather icon displays are based on the hourly calculation of indoor/ outdoor temperature and humidity data. The forecast is for next 12-24 hours.
MOON PHASE
The moon phase will be changed when calendar changes:
![BALDR - B0201WST2H2 - MOON PHASE MOON PHASE]()
PRECAUTIONS
- Do not clean any part of the product with benzene, thinner or other solvent chemicals. When necessary, clean it with a soft cloth.
- Never immerse the product in water. This can cause electrical shock and damage the product.
- Do not subject the product to extreme force, shock, or fluctuations in temperature or humidity.
- Do not tamper with the internal components.
- Do not mix new and old batteries or batteries of different types.
- Do not mix alkaline, standard or rechargeable batteries with this product.
- Remove the batteries if storing this product for a long period of time.
- Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
service@baldr.com
www.baldr.com
![]()
Documents / Resources
References
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download BALDR B0201WST2H2 - Weather Station with Thermometer and Humidity Manual
Need help?
Do you have a question about the B0201WST2H2 and is the answer not in the manual?
Questions and answers