CURRENT FAULT
Description/Action
Press Current Fault from the Main Menu to enter this menu. This
menu contains non adjustable operational information. Use the
Slidebar to navigate the menu.
This menu contains the current Fault or Alert error message. The
time the Fault or Alert message occurred appears directly below.
A brief description of what causes the particular Fault or Alert
condition appears below that. Pressing "ADVANCED" will give
more detailed service information and a list of possible causes for
the Fault or Alert condition. See Fault and Alert Messages on page
61 for more detailed information and diagnostic procedures.
If there is no Fault or Alert condition active this menu will not
contain any information, "(none)" will be shown next to Current
Fault in the Main menu.
FAULT HISTORY
Description/Action
Press "Fault History" from the Main Menu to enter this menu. This
menu contains non adjustable operational information. Use the
Slidebar to navigate the menu.
This menu contains a list of the last nine (9) Fault and Alert
messages with a time stamp. The newest event will replace the
oldest. Faults will clear after 30 days.
Press the Fault to view details for each Fault or Alert message
stored.
FAULT OCCURRENCE
Description/Action
Press Fault Occurrence from the Main Menu to enter this menu.
This menu contains non adjustable operational information. Use
the Slidebar to navigate the menu.
This menu contains a running total of how many times each Fault
condition has occurred since the water heater was first installed.
Note: Historical data is stored in the configuration key. If
this "key" is replaced during servicing the historical
data will be lost. The data stored in the new
configuration key will no longer reflect the entire
history of the water heater.
RESTORE FACTORY DEFAULTS
Description/Action
Press Restore Factory Defaults from the Main Menu to enter
this menu.
To restore the adjustable user settings to their factory default
settings press "YES." The display will show text confirming the
factory default settings have been restored.
Press NO to exit the Restore Factory Defaults menu.
Blocked Exhaust
0 days 0 hr 0 min ago
Error Code: A8-1201
Restriction in exhaust pipe.
Check exhaust pipe and
termination for blockage.
Press the Advanced button for
Fault History
1:
Upper Temp Probe (Open) (47) >
0 days 2 hrs 37 mins ago >
2:
Hardware Failure (1A) >
0 days 2 hrs 37 mins ago >
3: Upper Temp Probe (Open) (47) >
0 days 2 hrs 40 mins ago >
Fault Occurrence
Ignition Failure
ECO
Low Gas Pressure
Blocked Intake Air
Blocked Exhaust
External Input
Restore Defaults
Are you sure you want to restore
the system to the factory
defaults?
Ye s
51
Display
BACK
ADVANCED
Display
BACK
HELP
Display
0 >
0 >
1 >
1 >
1 >
0 >
BACK
HELP
Display
No

Advertisement

Table of Contents
loading

Table of Contents