Locating The Water Heater - State Water Heaters 301 Series Instruction Manual

Hide thumbs Also See for 301 Series:
Table of Contents

Advertisement

Table 2. Fuel Type/Connection Size by Model
† MODEL
SERIES
SUF 60120
300/301
SUF 100150
300/301
SUF 100199
300/301
SUF 100250
300/301
† Depending on the installed equivalent length, and/or the number of appliances con-
nected, the supply gas line size may have to be increased beyond the minimum re-
quired sizes - see Gas Line Sizing on page 40.
Model
NATURAL GAS PROPANE GAS
SUF 60120
0" W.C. (0 kPa) 0" W.C. (0 kPa) 3.5" W. C. (1.10 kPa) 8.5" W. C. (2.12 kPa) 14" W. C. (3.49 kPa) 14" W. C. (3.49 kPa)
SUF 100150
0" W.C. (0 kPa) 0" W.C. (0 kPa) 3.5" W. C. (1.10 kPa) 8.5" W. C. (2.12 kPa) 14" W. C. (3.49 kPa) 14" W. C. (3.49 kPa)
SUF 100199
0" W. C. (0 kPa) 0" W. C. (0 kPa) 3.5" W. C. (1.10 kPa) 8.5" W. C. (2.12 kPa) 14" W. C. (3.49 kPa 14" W. C. (3.49 kPa)
SUF 100250
0" W. C. (0 kPa) 0" W. C. (0 kPa) 3.5" W. C. (1.10 kPa) 8.5" W. C. (2.12 kPa) 14" W. C. (3.49 kPa) 14" W. C. (3.49 kPa)
Type of
Input
Model
Gas
Btu/hr
Natural
SUF 60120
120,000 35
Propane
Natural
SUF 100150
150,000 44
Propane
Natural
SUF 100199
199,900 58
Propane
Natural
SUF 100250
250,000 73
Propane

LOCATING THE WATER HEATER

Carefully choose a location for the new water heater. The
placement is a very important consideration for the safety of the
occupants in the building and for the most economical use of the
water heater.
CAUTION
Property Damage Hazard
All water heaters eventually leak.
Do not install without adequate drainage.
Whether replacing an existing water heater or installing the water
heater in a new location observe the following critical points:
1. The water heater must be located indoors.
2. The water heater must not be located in an area where it will
be subject to freezing temperatures.
3. Locate the water heater so it is protected and not subject to
physical damage by a moving vehicle.
4. Locate the water heater on a level surface.
5. Locate the water heater near a floor drain. The water heater
should be located in an area where leakage of the tank or
connections will not result in damage to the area adjacent to
the water heater or to lower floors of the structure. When such
locations cannot be avoided, it is recommended that a metal
drain pan, adequately drained, be installed under the water
heater.
6. Locate the water heater close to the point of major hot water
usage.
7. Locate the water heater close to a 120 VAC power supply. See
(page 13) for requirements.
Power Supply
8. Locate the water heater where an adequate supply of fresh
air for combustion and ventilation can be obtained. See
(page 17).
Requirements
NATURAL GAS
PROPANE GAS
3/4 "NPT
3/4 "NPT
3/4 "NPT
3/4 "NPT
3/4 "NPT
3/4 "NPT
3/4 "NPT
3/4 "NPT
Table 4. GAS PRESSURE REQUIREMENTS
*Manifold Pressure
NATURAL GAS
Table 5. RECOVERY CAPACITIES
Thermal
°F
30°F
kW
Efficiency%
°C
17°C
GPH
461
95
LPH
1743
GPH
594
98
LPH
2248
GPH
783
97
LPH
2965
GPH
970
96
LPH
3670
Table 3. Storage Capacities
MODEL
SUF 60120
SUF 100150
SUF 100199
SUF 100250
Minimum Supply Pressure
PROPANE GAS
U. S. Gallons/hr & liters/hr at temperature rise indicated
40°F
50°F
60°F
70°F
80°F
22°C
28°C
33°C
39°C
44°C
345
276
230
197
173
1308
1046
872
747
654
445
356
297
255
223
1686
1349
1124
963
843
588
470
392
336
294
2224
1779
1483
1271
1112
727
582
485
416
364
2753
2202
1835
1573
1376
9. Locate the water heater where the vent and intake air piping,
when installed, will remain within the maximum equivalent
lengths allowed. See
10. Do not locate the water heater where noise (such as
the Combustion Blower) during normal operation will be
objectionable in adjacent areas.
11. Do not locate the water heater where the subsequent installation
of the vent (exhaust) or intake air terminations would be
objectionable due to noise at the termination(s). This includes
locations close to or across from windows and doors. See
Venting Installation
Fire or Explosion Hazard
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Avoid all ignition sources if you smell gas.
Do not expose water heater controls to excessive gas
pressure.
Use only the gas shown on the water heater rating label.
Maintain required clearances to combustibles.
Keep ignition sources away from faucets after extended
periods of non-use.
Read instruction manual before
installing, using or servicing
There is a risk in using fuel burning appliances such as gas water
heaters in rooms, garages or other areas where gasoline, other
flammable liquids or engine driven equipment or vehicles are
stored, operated or repaired. Flammable vapors are heavy and
Air
travel along the floor and may be ignited by the water heater's
igniter or Main Burner flames causing fire or explosion.
11
U. S. GALLONS
LITERS
60
227
100
379
100
379
100
379
Maximum Supply Pressure
NATURAL GAS
PROPANE GAS
90°F
100°F
110°F
120°F
130°F
50°C
56°C
61°C
67°C
72°C
154
138
126
115
581
523
475
436
198
178
162
148
749
674
613
562
261
235
214
196
988
890
809
741
323
291
264
242
1223
1101
1001
918
(page 22).
Venting Requirements
(page 21).
water heater.
140°F
78°C
106
99
402
374
137
127
519
482
181
168
684
635
224
208
847
786

Advertisement

Table of Contents
loading

Table of Contents