Function
Description
CONF-EXPORT
Export configuration
file
CONF-IMPORT
Export configuration
file
COM-ROUTE?
Get tunneling port
routing.
This command sets
tunneling port routing.
Every com port can
send or receive data
from the ETH port.
Set command can edit
an existing
configuration.
COUNTER?
Get the sent or
received CEC
messages count.
COUNTER-CLR
Clear CEC messages.
DEV-STATE?
Get the device state.
ETH-PORT
Set Ethernet port
protocol.
If the port number
you enter is already in
use, an error is
returned.
The port number must
be within the following
range: 0-(2^16-1).
ETH-PORT?
Get Ethernet port
protocol.
If the port number
you enter is already in
use, an error is
returned.
The port number must
be within the following
range: 0-(2^16-1).
ETH-TUNNEL?
Get an open tunnel
parameters.
FACTORY
Reset device to factory
default configuration.
This command
deletes all user data
from the device. The
deletion can take
some time.
Your device may
require powering off
and powering on for
the changes to take
effect.
SWT3-41-U-T – Protocol 3000
Syntax
COMMAND
#CONF-EXPORT<CR>
FEEDBACK
file_name<CR><LF>
~nn@CONF-EXPORT
COMMAND
#CONF-IMPORTfile_name<CR>
FEEDBACK
~nn@CONF-IMPORTfile_name<CR><LF>
COMMAND
#COM-ROUTE?com_id<CR>
FEEDBACK
~nn@COM-ROUTEcom_id,port_type,port_id,eth_rep_en,pin
g_val<CR><LF>
COMMAND
#COUNTER?category_id,sub_category_id<CR>
FEEDBACK
~nn@COUNTERcategory_id,sub_category_id,count<CR><LF>
COMMAND
#COUNTER-CLR?category_id,sub_category_clr<CR>
FEEDBACK
~nn@COUNTER-
CLRcategory_id,sub_category_id,count<CR><LF>
COMMAND
#DEV-STATE?<CR>
FEEDBACK
~nn@DEV-STATEdev_state<CR><LF>'
COMMAND
#ETH-PORTport_type,port_id<CR>
FEEDBACK
~nn@ETH-PORTport_type,port_id<CR><LF>
COMMAND
#ETH-PORT?port_type<CR>
FEEDBACK
~nn@ETH-PORTport_type,port_id<CR><LF>
COMMAND
#ETH-TUNNEL?tunnel_id<CR>
FEEDBACK
~nn@ETH-TUNNELtunnel_id,cmd_name,port_type,port_id,e
th_ip,remote_port_id,eth_rep_en,connection_type<CR><L
F>
COMMAND
#FACTORY<CR>
FEEDBACK
~nn@FACTORYok<CR><LF>
Kramer Electronics Ltd.
Parameters/Attributes
the name of the file we
file_name -
want to upload for the import.
– Machine dependent, * (get
com_id
all route tunnels)
– TCP/UDP
port_type
0 – TCP
1 – UDP
– TCP/UDP port number
port_id
– Ethernet Reply
eth_rep_en
0 – COM port does not send replies
to new clients
1 – COM port sends replies to new
clients.
– Send an empty string to
ping_val
TCP client every 0 to 3600 seconds. 0 -
3600
– CEC messages: 0
category_id
– Type of
Sub_category_id
message:
0 – Sent message
1 – Received message
– Number range: 0-65535
count
– CEC messages: 0
category_id
– Type of
Sub_category_clr
message to clear:
0 – Clear sent messages
1 – Clear received messages
* – Clear all CEC messages
dev_state
– device state
0 – Active
1 – Power-on and no connected AV
I/O ports (detecting cable
connection faults)
2 – Power-on and standby (low
power; cables are either
connected or not)
– TCP/UDP
port_type
– TCP/UDP port number
port_id
(0 – 65535)
port_type
– TCP/UDP
port_id
– TCP/UDP port number
(0 – 65535)
– Tunnel ID number, * (get
tunnel_id
all open tunnels)
– UART number
cmd_name
port_type
– TCP/UDP
0 – TCP
1 – UDP
– TCP/UDP port number
port_id
– Client IP address
eth_ip
remote_port_id
– Remote port
number
– Ethernet Reply
eth_rep_en
0 – COM port does not send replies
to new clients
1 – COM port sends replies to new
clients
– Connection type
connection_type
0 – not wired connection
1 – wired connection
Example
Export configuration file:
#CONF-EXPORT<CR>
Import configuration file:
#CONF-IMPORT
SWT3-
41-U-T-conf<CR>
Get tunneling port routing
for all route tunnels:
#COM-ROUTE?*<CR>
Get the number of sent
messages:
#COUNTER?0,0<CR>
Clear all CEC messages:
#COUNTER-CLR?0,*<CR>
Get device status:
#DEV-STATE?<CR>
Set the Ethernet port
protocol for TCP to 12457:
#ETH-PORTTCP,12457<C
R>
Get the Ethernet port
protocol for UDP:
#ETH-PORT?UDP<CR>
Set baud rate to 9600, 8
data bits, parity to none and
stop bit to 1:
#ETH-TUNNEL?*<CR>
Reset the device to factory
default configuration:
#FACTORY<CR>