Siemens SIMATIC NET RUGGEDCOM MX5000 Equipment Manual page 61

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM MX5000:
Table of Contents

Advertisement

Certification
6.3 EMC and Environmental Type Tests
Environmental Type Tests
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
52
Description
Dielectric Strength
Test
Cold Temperature
Dry Heat
Humidity (Damp
Heat, Cyclic)
DC Power ports
AC Power ports
Signal ports
DC Power ports
AC Power ports
Description
Test Ad
Test Bd
Test Db
Vibration
Shock
Test Levels
5 kV
5 kV
2 kV
2 kV
2 kV
Test Levels
-40 °C (-40 °F), 16 Hours
85 °C (185 °F), 16 Hours
95% (non-condensing),
55 °C (131 °F), 6 cycles
2 g @ 10 - 150 Hz
30 g @ 11 mS
RUGGEDCOM MX5000
Equipment Manual, 11/2023, C79000-G8976-1059-16

Advertisement

Table of Contents
loading

Table of Contents