3.3.1

Permitted inclination

NOTICE
INSUFFICIENT LUBRICATION!
Excessive inclination results in irregular level of
lubricant in the housing.
Observe the maximum permitted inclination of
the screw compressor during operation:
·
To the front and to the rear: 10°
·
To the right and left: 10°
3.4

Preparing installation

The approximate position of the compressor and the compressor unit on the vehicle must be determined
prior to the installation considering the following framework conditions.
Accessibility to the oil pressure gauge, negative pressure indicator, oil dipstick or oil inspection glass, oil
drain plug or oil intake strainer must be taken into consideration during installation.
NOTE
The exact position of the compressor unit on the vehicle can only be determined in the course of a trial
assembly after completing the compressor unit.
3.4.1

Required space conditions for the compressor kit and compressor unit

Check the space required on the truck on the right‑hand side (in the direction of travel), taking into con‑
sideration the respective unit dimensions.
Dimensions of the line of products, see Chapter 1.7 on page 9 to Chapter 1.8 on page 12.
3.4.2

Checking the direction of rotation

Check that the direction of rotation of the compressor model (as ordered) matches the direction of rota‑
tion of the vehicle engine's power take-off (viewed in the direction of travel):
If the power take-off rotates in anti-clockwise direction, install the CS104 R compressor unit.
If the power take-off rotates in clockwise direction, install the CS104 L compressor unit.
3.4.3

Aligning the compressor on the vehicle/flange parallelism

Installation and alignment of the compressor unit must be carried out so that the flange of the overload
coupling installed on the compressor is aligned parallel to the articulated shaft flange of the power take-
off.
NOTE
The mounting consoles of the CS1200 LITE compressor kit and the CS1200 ICL compressor unit are
supplied with an inclination (per drill pattern) of 3° (Chapter 1.8 on page 12).
47757787 A
Installation guidelines