4.8 Syphon Part Removal

Isolate the appliance from powersupply and closedown
the gas valve.
Drain the water from the boiler (refer to Section 4.1).
Remove the condensate syphon hose's drain pipe (refer
to Section 4.1)
Remove the syphon part that by holding body part (1,2).
B
INFORMATION
Ensure the syphon part's o-ring and gaskets
mounted correctly.
D2CND028A1AA + D2CND028A4AA + D2CND035A1AA +
D2CND035A4AA + D2TND028A4AA + D2TND035A4AA
Wall-mounted condensing boiler
ESIE17 - 09 / 2017.11
(1,2)
4.9 Expansion Vessel Removal
Isolate the appliance from power supply and closedown
the gas valve.
Drain the water from the boiler ( refer to Section 4.1 ).
Open the appliance (refer to Section 4.2 ).
Remove the left cover of the boiler ( unscrew the screws
that connects hermetic cabin and left cover)(1).
Disconnect the expansion vessel hose by using wrench.
(2)
Remove washers and nuts that connnect expansion ves-
sel and hermetic cabinet (3).
Take out the expansion vessel from the appliance (4).
(1)
(3)
(4)
Re-assemble in reverse order.