Daikin D2CND028A1AA Servicing Manual page 13

Wall-mounted condensing boiler
Hide thumbs Also See for D2CND028A1AA:
Table of Contents

Advertisement

Dismantle earth connection of electric supply wire (11).
D2CND028A1AA + D2CND028A4AA + D2CND035A1AA +
D2CND035A4AA + D2TND028A4AA + D2TND035A4AA
Wall-mounted condensing boiler
ESIE17 - 09 / 2017.11
Push DHW temperature sensor socket's housing right-
ward kindly by manually (12).
Take out the connector's nails from the socket's housing
and disconnect the sensor (13) ( It is used only C- model)
Take out cable connections of fan manually (14).
(11)
Re-assemble in reverse order (Be careful all electrical
cables during the removal of cable group(wire harness)).
Power supply cable's ends must be install to electrical
fuse directly ( it should't be use contact socket).
NOTICE
Power supply cable (230 VAC) is connection to
the wire harness. Therefore, all electrical leads
connection must be taken out so that disconnect
the power supply cable.
4 Part replacement
(13)
(12)
(14)
Servicing manual
13