PRESET

PRESET
Please consult nexo-sa.com for NEXO TD Controllers firmware information.
There are two setting range for surrounding speaker L18:
→ "OMNI" Setups; For a traditional use of the subwoofer in omnidirectional radiation (require at least one subwoofer and a
channel of amplifier).
Omnidirectional Main setup, with low-pass at 60, 85 or 120 Hz.
Omnidirectional Monitor setup, with low-pass at 60, 85 or 120 Hz.
→ "CARDIO" Setups; For a directional use (cardioid) of subwoofers (require at least two subwoofers and two channels of
amplifier).
Cardioid back and front setups, with low-pass at 60, 85 or 120 Hz.
Setup « FR » (Front) for the subwoofer pointed at the audience.
-
Setup « BA » (Back) for the subwoofer turned around.
-
The ideal ratio for a directional use is 2x L18 in CARDIO FRONT mode on top of 1x Reversed L18 in CARDIO BACK
mode. From 1:1 to 3:1 ratio can be used.