Gree ALTEA Service Manual page 38

Table of Contents

Advertisement

Note of Installingheat discharge pipe
The length of the heat discharge pipe is less than 40 inchs. It is recommended to use it with shortest length.
When installing,heat discharge pipe should be as flat as possible. Don't prolong the pipe or connect it with other heat
discharge pipe.
Disassemble heat discharge pipe
1. Remove joint:
Press the clasp and lift joint upwards to remove it.
36
The discharge pipe is suggested to be installed according to below figure by the manufacturer.
correct
User can adjust the installation method of the discharge pipe basing on the requirement, while
the similar installation methods as below which will lead to unsmoothly air-out are not allowed.
wrong
clasp
under 51 inchs
about 24 inchs
heat discharge pipe.
upwards
disassemble
joint