6.1.5. The fuses trip frequently

6.1.6. The machine cannot cope

Tip!
Check the minimum recommended cable area before using an
extension cord. You will find the recommended cable area under
Technical Data on page 34.
1.0
The load is too high on the distribution box to which the
machine is connected. Use a different socket or reduce the
speed of the machine.
Check the tools. Ensure that the correct tools are used, that
they are in working order and that they are correctly fitted.
Heavy load. Press the handle down slightly so that the
grinding head eases away slightly from the surface being
ground.
Sticky coating on the surface being ground. Run half of the
machine on the surface to be cleaned and half on the clean
surface. This removes any residue from the tools.
Check the tools. Ensure that the correct tools are used, that
they are in working order and that they are correctly fitted.
Voltage drop. Check that the cable area meets HTC's
recommendations.