Page 1
All leak tests should be done with a soapy water solution. Never use an open flame to check for leaks! Validity These installation instructions apply to the following models: Model number Type Appliance class 31046 GAS311EKBZ Class 3 DIN EN 30-1-1 31050 GAS321EKBZ 31056 GAS731EKBZ...
Page 2
1009430-10 Installation instructions 26/07/2023 Built-in variants of gas hob Dials GAS311/321/731 1009430-10 Installation accessories provided For all installation variants: Designation Art. no. 4 adjusting braces H61561 Sealing ring gas connection 18 × 13 × 1.5 mm H64006 Flush installation: Designation Art.
1009430-10 Installation instructions 26/07/2023 Built-in variants of gas hob Dials GAS311/321/731 1009430-10 Surface-mounted installation The layout of the hob to be fitted may differ from the hob illustrated! GAS311EKBZ/GKBZ GAS321EKBZ/GKBZ GAS731EKBZ/GKBZ Y – Y T ≥90 Drawer/ Side panel cabinet...
1009430-10 Installation instructions 26/07/2023 Built-in variants of gas hob Dials GAS311/321/731 1009430-10 Flush installation The layout of the hob to be fitted may differ from the hob illustrated! GAS311EKBZ/GKBZ GAS321EKBZ/GKBZ GAS731EKBZ/GKBZ Detail Z Y – Y R0–5 T ≥90 Drawer/...
1009430-10 Installation instructions 26/07/2023 Built-in variants of gas hob Dials GAS311/321/731 1009430-10 ▸ Carefully cement the appliance in and leave the silicone sealant to dry for at least 24 hours. ▸ Connect to the electrical mains connection before inserting the appliance, if necessary. Combination installation Flush-mounted combination installation is described in document 1014381.
1009430-10 Installation instructions 26/07/2023 Built-in variants of gas hob Dials GAS311/321/731 1009430-10 Minimum distances and installation conditions The distance from the appliance cut-out to the back wall must be ≥50 mm and to the side walls ≥200 mm. Parts such as side walls and reinforcing strips which protrude into the installation space under the cooking zone must be made of fire-resistant material.
Page 7
1009430-10 Installation instructions 26/07/2023 Built-in variants of gas hob Dials GAS311/321/731 1009430-10 Thread length Thread length of gas connection on the appliance (external thread) So is 16 mm. If the thread length of the on-site counterpart (internal thread) Si is longer than 17 mm, the front-end seal is no longer guaranteed through the supplied green sealing ring H64006 with a height of 1.5 mm.
Change injector nozzles using a 7-inch socket wrench or corresponding wrench. Designation Injector, ø in hundredths of a mm Bypass, ø in hundredths of a mm / letter code For the appliances GAS311EKBZ/GKBZ and GAS321EKBZ/GKBZ, the following gas types are available: Gas type Test gas Connection Wok burner...