4. Connect new SITRANS CC220.
5. Reconnect old SITRANS MS200 with SITRANS SCM IQ to the same MindSphere asset.
6. Reset SITRANS MS200.
AUTOHOTSPOT
6.2.5

Updating firmware of SITRANS CC220

Introduction
If a firmware update is required, you receive a notification in SITRANS SCM IQ.
Procedure
1. Download the firmware update file for SITRANS CC220.
Dowload firmware update file for SITRANS CC220
support.industry.siemens.com/cs/ww/en/ps/28832/dl)
2. Plug in an empty and fat32 formatted USB stick with 16 GB free disk space into your PC.
3. Store the *.SWU file on the USB stick.
4. Insert the USB stick into SITRANS CC220 USB 1-X60 port.
⇒ USER LED 2 is blinking green (takes 5 to 10 minutes).
⇒ Both USER LEDs are blinking orange while the firmware update is ongoing (takes 5 to 10
minutes). We recommend you to remove the USB stick from SITRANS CC220.
⇒ If the firmware update passed the USER LEDs light green for 10 seconds.
⇒ SITRANS CC220 reboots.
If firmware update fails
⇒ USER 1 LED is blinking orange.
⇒ USER 2 LED is blinking red.
To go back to old working state, press RESET button, and SITRANS CC220 will reboot.
6.3

Maintenance and repair work for SITRANS MS200

6.3.1

Basic safety notes

The device is maintenance-free. However, a periodic inspection according to pertinent directives
and regulations must be carried out.
An inspection can include, for example, check of:
• Ambient conditions
• Seal integrity of the cover
SITRANS CC220 and SITRANS MS200
Compact Operating Instructions, 10/2023 - DRAFT, A5E...-AA
6.3 Maintenance and repair work for SITRANS MS200