Installing/mounting
3.2 Installation instructions SITRANS MS200
3.2.1.1

Installation location requirements

NOTICE
Aggressive atmospheres
Damage to device through penetration of aggressive vapors.
• Ensure that the device is suitable for the application.
NOTICE
Direct sunlight
Damage to device.
The device can overheat or materials become brittle due to UV exposure.
• Protect the device from direct sunlight.
• Make sure that the maximum permissible ambient temperature is not exceeded. Refer to
3.2.2

General description

NOTICE
Wrong assembly
Wrong assembly can damage the asset or the SITRANS MS200.
• Carefully read the safety instructions before mounting.
SITRANS MS200 has an M8 female thread for the installation, see Dimension drawings
SITRANS MS200.
For thread M8:
• minimum screw-in depth 5,5 mm
• maximum screw-in depth 13 mm
• screw-in torque min. 18 Nm and max. 20 Nm
• screw-in material stainless steel
Use an anaerobic adhesive thread locker.
SITRANS MS200 can be mounted in various ways utilizing its threaded M8 hole. As examples
for mounting you can:
• directly mount SITRANS MS200 to an existing stud bolt
• use a short threaded bolt to mount SITRANS MS200 to a threaded hole
• use a clamp shell to mount SITRANS MS200 to a pipe