Property
PROFINET IO
PROFINET interface (X1 P1R
and X1 P2R)
PROFINET interface (X2 P1) The interface has one port. In addition to basic PROFINET
Operation of the CPU as
•
IO controller
•
I-device
Accessories
You can find information on "Accessories/spare parts" in the S7-1500, ET 200MP system
manual (https://support.industry.siemens.com/cs/ww/en/view/59191792).
3.4
Firmware functions
Functions
The CPU 1515‑2 PN supports the following firmware functions:
Function
Integrated system
diagnostics
Integrated Web server
Integrated trace
functionality
CPU 1515-2 PN (6ES7515-2AN03-0AB0)
Equipment Manual, 11/2022, A5E46416198-AC
Description
The interface has two ports. In addition to basic
PROFINET functionality, it also supports PROFINET IO RT
(real time) and IRT (isochronous real time).
functionality, it also supports PROFINET IO RT (real time).
•
IO controller:
As an IO controller, the CPU addresses the connected
IO devices
•
I‑device:
As an I-device (intelligent IO device), the CPU is
assigned to a higher-level IO controller and is used in
the process as an intelligent pre-processing unit of
sub-processes
Description
The system automatically generates the alarms for the
system diagnostics and outputs these alarms via a pro
gramming device/PC, HMI device, the Web server or the
integrated display. System diagnostics information is also
available when the CPU is in STOP mode.
The Web server lets you access the CPU data by means of
a network. Evaluations, diagnostics, and modifications
are thus possible over long distances. Monitoring and
evaluation is possible without STEP 7; all you need is a
Web browser. Make sure that you take appropriate meas
ures (e.g. limiting network access, using firewalls) to pro
tect the CPU from being compromised.
Trace functionality supports you in troubleshooting
and/or optimizing the user program.
You record device tags and evaluate the recordings with
the trace and logic analyzer function. Tags are, for
example, drive parameters or system and user tags of a
CPU.
The device saves the recordings. You can read out and
permanently save the recordings with the configuration
system (ES), if required. The trace and logic analyzer
Product overview
3.4 Firmware functions
Additional information
PROFINET
(https://support.industry.siemens.
com/cs/ww/es/view/49948856) func
tion manual
Additional information
Diagnostics
(https://support.industry.siemens.
com/cs/ww/en/view/59192926) func
tion manual
•
Web server function manual
(https://support.industry.siemens.
com/cs/ww/en/view/59193560)
•
Security with SIMATIC S7 control
lers system manual
(https://support.industry.siemens.
com/cs/ww/en/view/90885010)
Function manual for trace and logic
analyzer function
(http://support.automation.siemens.
com/WW/view/en/64897128)