Download Print this page
HDL MWC1-BP.10 Instruction Manual

HDL MWC1-BP.10 Instruction Manual

Curtain motor

Advertisement

Quick Links

Curtain Motor
Instruction Manual
MWC1-BP.10
Before using this product, please read this manual carefully and keep it properly!
Document Version:V1.0

Advertisement

loading

Summary of Contents for HDL MWC1-BP.10

  • Page 1 Curtain Motor Instruction Manual MWC1-BP.10 Before using this product, please read this manual carefully and keep it properly! Document Version:V1.0...
  • Page 2 Note: The pictures and illustrations provided in this instruction manual are for reference purposes only, and the actual product may differ. Key Functions: HDL Buspro communication protocol • Curtain control: Open / close / stop / open or close at specific percentage •...
  • Page 4 Motor input voltage 100 - 240V AC, 50/60Hz Motor rated consumption BUS input voltage 12 - 30V DC BUS rated voltage 24V DC BUS rated current 10mA/24V DC Motor torque 1.2 N·m Motor rotate speed 90rpm Motor maximum load-bearing 50kg Motor sound level <30dB at silent mode Communication protocol...
  • Page 5 Dimensions(W X H X D) 296×71×50.6mm (See Figure 3 - 5) Net weight 724g Housing material PC, aluminium Installation Guide rail (See Figure 7 & 8) IP degree (compliant with EN 60529) IP41 Insultation grade...
  • Page 6 Warning: The installation and testing for the product must be carried out by HDL Automation Co., • Ltd. (hereinafter referred to as HDL) or its appointed service agencies. The electric con- struction shall comply with local laws and safety regulations.
  • Page 7 Tips: For Buspro connection, a hand-in-hand connection is recommended. Note: In addition to Buspro connection, please note to connect the device with 220V AC power supply. HDL Buspro Cable Guide Inner Buspro HDL Buspro Cable CAT5/CAT5E DATA+ Yellow Blue/Green DATA-...
  • Page 8 Warning: Before performing any installation procedures on the device, it is crucial to dis- connect the device from all voltage sources. This step is necessary to ensure the safety of the technician and prevent any potential damage to the device. Tips: The device should be mounted onto the guide rail.
  • Page 9 The device is configured with one programming button and indicator, as described below. Note: All operation and settings described as below should be carried out when the device is running normally. 1.1. Switch Power-on to Quick Start Operation Status of Indicator Connect the device to power supply, then it starts Red light is on for 10s then off.
  • Page 10 There are three options for users to proceed advanced settings for curtain motor. In this sec- tion, it gives information about part of the settings rather than all. Commissioning software: HDL Studio is the software applicable for users to proceed ad- •...
  • Page 11 2.4. Erase Trave Limit Tips: Travel limit can be erased by commissioning software or programming button. In this section, it only gives information about the latter. Operation Status of Indicator Status of Motor Remark Long press programming button for After successfully Red light is on then 5s, then immediately release until set, the motor ro-...
  • Page 12 2.7. Learning Codes in Remote Controller There are two options for pairing the device with remote controller, as described below. Re- garding operations about further learning codes, please refer to the datasheet of the remote controller used. Tips: Inside the remote controller used, users will see each side of the battery compartment has a channel setting button (see Figure 10), which is used for pairing the remote controller and the corresponding motor, then receiving and processing further learning codes.
  • Page 13 • Note: After unpacking, please check if the product and the parts are complete. HDL has all the intellectual property rights to this document and contents thereof. Repro- duction or distribution for third parties are prohibited without written authorization from HDL.