Cables: (Item 4 ~6 for Full function model only)
1.
Audio in: Plug microphone into RCA audio in port (Red color).
2.
Audio out: Plug speaker into RCA audio out. (White color).
3.
RJ-45 Female connector (Waterproof): Plug to RJ-45 connector (Male) to extent the
transmission distance via UTP cable; then connect to POE Hub.
4.
Alarm in #1: Alarm in for sensor input (Red/Black wire)
5.
Alarm in #2: Alarm in for sensor input (Yellow/Black wire)
6.
Alarm Out: Alarm out (Orange/ Purple wire) for relay trigger.
7.
Reset: Press 20 seconds the reset button and the camera parameters will become to default.
8.
Power cable: Connect to DC12V power adapter when use none POE Hub.

Wall Mount installation

Fix the camera
This camera is waterproof and in compliance with the IP66 spec, but the jack connected to the
external cable is not. You are recommended to install this product below the edge of eaves to prevent
the cable from being externally exposed.
1) Paste the mount hole sticker on the position that you want to install. (Fig 1)
2) Use the mount hole sticker to make a hole of 30mm in diameter for passing cable, and drill
another three holes on the wall to fix bracket mount. (Fig 2)
3) Insert the anchors to fix the screws with the Mount panel. (Fig 3)
4) Fix camera with Mount panel, then adjust 5 degree of Anti-clock. (Fig 4)
Fig 1
Fig 2
Fig 3
3