The level-4 user is able to:
a) Update the firmware and language files at the control unit automatically or using the web
interface.
b) Log into the user menu or web interface and change the level-4 user name and code.
The level-4 user cannot perform other tasks, such as to set or unset the system, omit zones, etc.
Activity Monitor
Use this option to enable or disable the activity monitor function which is the inversion of
detectors for social care monitoring.
To switch facilities on or off:
1. Select System Config – Facilities On/Off .
2. Use
or
to choose the facility, then
3. Press 4.
4.13.2
Setting the date and time
You can use System Config – Set Date & Time to set the date and time. You may need to do this if, for
example, the control unit lost all power for an extended period of time.
Select the option, enter the date (dd/mm/yyyy) and then the time.
Note: The installer may have set up the control unit to obtain its time automatically from the ABUS
Cloud service. The internal clock adjusts itself for daylight saving in Spring and Autumn.
4.13.3
Configuring calendar sets
You can use System Config – Calendar Set to configure the control unit to set, part set or unset any
collection of partitions of the alarm system at fixed times of day on a seven-day cycle. There are two basic
elements that you can program within the calendar set option: the "event" and the "exception". An event
defines an action (setting, part setting or unsetting) to occur regularly at set times and days. An exception
defines periods such as holidays when you do not want the event to occur. The number of events and
exceptions the control unit can store is dependent on the control unit model.
Hint: Set up exceptions first, and then the events.
Note:
• You should not program an event to change the system/partition directly from one part set level
to another. You should program an event to unset the system/partition first, and another event to
set the system/partition to a different part set level. For example, if event 01 part sets the system
(or a partition), do not program event 02 to full set the system. Instead, program event 02 to unset
the system and then use event 03 to full set the system.
• If you create an event to unset a partition, and another event to set the same partition again, you
must program the setting event to occur at least 10 minutes after the unsetting event.
26
or
to switch it on or off.
Using the system